12
PJ-TX10 (C10H)
Power can not be turned on
Are
voltage input
at pins
,
,
,
of
E800 on the PWB assembly
Main at standby
mode?
: 0V
: +17V
: +6.6V
: +4.1V
Power unit (circuit)
Lamp door SW
Fuse
on the Filter unit
Filter unit
Reset the Lamp door
NO
YES
Disconnect
TSW form Power unit
(circuit). And check
TSW short or
open?
PWB assembly Main
Short
YES
TSW
Open
Is the Lamp door installed
correctly?
NO
What is the state of
TEMP indicator D302?
Not light
Blinks
Jump to * on the page 13
1
1
3
5
7
3
5
7