28
LEVEL
: Setting value
306Axxzz
h
xx: 80h to 7Eh signed zz: undefined
6. Focus detection function
Integrated or peak value of sharpness signal is automatically calculated in every field. The value is available for
auto focus system.
(1)
FOCUS
GATE
Set position and size of focus gate where the focus data is calculated.
-INDIGATE-
Focus gate window is selectable visible(ON) / invisible(OFF).
Setting
value
20170xF3
h
x: 0- OFF, C- ON
-GATE POSITION-
H POSITION
: Setting value
30B1xxzz
h
xx: AFh to 51h signed [HV-F22] / C4h to 3Ch signed [HV-F31], zz: undefined
V POSITION
: Setting value
30B2xxzz
h
xx: C4h to 3Ch signed [HV-F22] / D4h to 2Ch signed [HV-F31], zz: undefined
-GATE SIZE-
WIDTH
: Setting value
30B3xxzz
h
xx: 00h to 14h [HV-F22] / 00h to 0Fh [HV-F31], zz: undefined
HEIGHT
: Setting value
30B4xxzz
h
xx: 00h to 0Fh [HV-F22] / 00h to 0Bh [HV-F31], zz: undefined
(2)
FOCUS
DETECTION
Returns focus data.