Variable:
Setting of variable electronic shutter speed (In the SHUTTER: Var. mode ) 1/1 to 1/30
(1/25 PAL): Long time integration mode
The video signal is out intermittently from the camera. To obtain a continuous picture, an
image memory or the like is required.
1/60.15 (1/50.15PAL) to 1/10168 (1/10040 PAL): Lock scan mode
EXTERNAL:
Setting of Field-on-Demand function (in the SHUTTER: EXT mode)
The electronic shutter can be operated at the desired timing and exposure time.
One TRIG mode:
The desired shutter speed can be set by a pulse width.
Two TRIG mode:
The desired shutter speed can be set by the interval between two trigger pulses.
FIX TRIG mode :
The electronic shutter operates for approximately 1/1600 for an input pulse.
EXT TRIG mode:
Only exposure time can be controlled by inputting one pulse. SYNC is not reset.
NOTE: For the use of the Field-On-Demand function, contact your local
Hitachi Denshi sales representative for more detail information’s..
DTL:
DTL amount control
Select OFF, LOW, NORM or HIGH
GAMMA:
Gamma ON/OFF
CONTRAST:
Contrast ON/OFF
When ON is selected, the contrast of dark portion is enhanced.
KNEE:
Knee ON/OFF
When ON is selected, the gradation of white portion becomes natural.
FLD/FRM:
Integration mode of CCD
FLD mode
The field integration mode is established. (Normal use)
FRM mode
The frame integration mode is established.
Note
1. In this mode, vertical resolution is increased, but after image is increased.
Therefore, this mode is effective for still picture
2 Do not use this mode in the SHUTTER:AES mode.
IRIS GATE:
The IRIS GATE menu is executed.
LENS:
The LENS Menu is executed.
RETURN:
The MAIN MENU is displayed.