Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification
230
20.1.5 Unit Attention Condition
The drive will generate a unit attention condition for each Initiator whenever these conditions are in effect:
•
The drive has been reset. This includes Power On Reset, SCSI Bus Reset, SCSI TARGET RESET message.
•
Another Initiator has changed the Mode parameters in effect for this Initiator.
•
Another Initiator issued a Log Select, thus clearing log parameters.
•
The microcode has been changed. WRITE BUFFER command has been executed to download microcode. In this
case a unit attention condition is generated for all Initiators except the one that issued the command.
•
Commands are cleared by another Initiator. This condition is generated against the Initiator that has queued com-
mands if
- a Clear Queue Message is received
- a Contingent Allegiance Condition is cleared when QERR (in Mode Page 0A) is 1
- a DQue is set to 1 while queued commands exist
•
SCSI Bus transceiver mode change (LVD <==> Single Ended).
•
Another Initiator preempted Reservations or Registrations.
•
A Predictive Failure Analysis threshold has been reached.
The unit attention condition persists for each Initiator until that Initiator clears the condition as described in the following para-
graphs.
If the drive receives a command from each Initiator before reporting a
Check Condition
status for a pending unit attention
condition for that Initiator, the response of the drive varies with the command as follows:
INQUIRY
The drive executes the command with
Good
status and preserves the unit attention condition.
REQUEST SENSE
If the drive has an available pending sense data for the Initiator, the drive sends the pending sense
data and preserves the unit attention condition for the Initiator. If the drive does not have an avail-
able pending sense data for the Initiator, the drive sends sense data for the unit attention condition
and clears the unit attention condition for the Initiator.
ALL OTHER
The drive terminates the command with a
Check Condition
status and preserves the unit attention
condition.
If the drive receives a command from each Initiator after reporting a
Check Condition
status for a pending unit attention con-
dition for that Initiator, the response varies with the command as follows:
REQUEST SENSE
The drive sends the sense data for a pending unit attention condition, returns
Good
status, and
clears the unit attention condition for the Initiator.
ALL OTHER
The drive executes the command with
Good
status and clears the unit attention condition, unless
another unit attention condition exists. The sense data for the unit attention condition is then lost.
Summary of Contents for HUS151414VL3600
Page 2: ...HItachi Ultrastar 15K147 SCSI Hard Disk Drive Specification ...
Page 18: ...HItachi Ultrastar 15K147 SCSI Hard Disk Drive Specification ...
Page 20: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 2 ...
Page 22: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 4 ...
Page 24: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 6 ...
Page 34: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 16 ...
Page 36: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 18 ...
Page 38: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 20 ...
Page 52: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 34 ...
Page 58: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 40 ...
Page 60: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 42 ...
Page 70: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 52 ...
Page 72: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 54 ...
Page 74: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 56 ...
Page 76: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 58 ...
Page 160: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 142 ...
Page 226: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 208 ...
Page 244: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 226 ...
Page 297: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 279 ...
Page 298: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 280 ...
Page 302: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 284 ...
Page 314: ...Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification 296 ...