7K200 SATA OEM Specification
139/173
14.37
Set Multiple (C6h)
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0 Register
7 6 5 4 3 2 1 0
Data
- - - - -
-
-
- Data
- - - - - -
-
-
Feature
- - - - -
-
-
- Error
...See
Below...
Sector Count
V V V V V V V V Sector Count
- - - - - -
-
-
LBA
Low
- - - - -
-
-
- LBA
Low
- - - - - -
-
-
LBA
Mid
- - - - -
-
-
- LBA
Mid
- - - - - -
-
-
LBA
High
- - - - -
-
-
- LBA
High
- - - - - -
-
-
Device
- - - - -
-
-
- Device
- - - - - -
-
-
Command
1 1 0 0 0 1 1 0 Status
...See
Below...
Error Register
Status Register
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
CRC UNC 0
IDN
0 ABT T0N
AM
N
BSY RDY
DF DSC DRQ
COR IDX
ERR
0 0 0 0 0 V 0 0
0 V 0 - - 0 0 V
Table 107 Set Multiple Command (C6h)
The Set Multiple command enables the device to perform Read and Write Multiple commands and
establishes the block size for these commands. The block size is the number of sectors to be
transferred for each interrupt.
The default block size after power up is 0, and Read Multiple and Write Multiple commands are
disabled.
If an invalid block size is specified, an Abort error will be returned to the host, and Read Multiple
and Write Multiple commands will be disabled.
Output Parameters To The Device
Sector Count
The block size to be used for Read Multiple and Write Multiple commands. Valid
block sizes can be selected from 0, 1, 2, 4, 8 or 16. If 0 is specified, then Read Multiple
and Write Multiple commands are disabled.