Replacing a fan
Replace a fan assembly, which is one of the server's hot-swappable components, as
follows:
Procedure
1. Remove the front bezel. The fan assemblies are now visible.
2. Identify the fan to be replaced.
Fans are labeled on the chassis, and are numbered 1 and 2, with fan 1 on the left
and fan 2 on the right. Refer to the fan status LEDs on front panel of the server
(behind the bezel) to see which fan has failed. In the following figure, number 1
indicates the status LED for fan 1 (the left-side fan), and number 2 indicates the
status LED for fan 2 (the right-side fan).
Figure 13 Fan status LEDs
Table 22 Fan status LED descriptions
Item
Description
1
Fan 1 status LED
2
Fan 2 status LED
3. Remove the faulty fan by loosening the thumbscrews (turning them counter-
clockwise) until they are loose, then pulling the fan unit straight out of the chassis.
(The fan lead connector disengages automatically as you remove the fan assembly.)
4. Put the new fan assembly into place.
5. Gently press the fan assembly back into the chassis. The fan electrical connector is
aligned automatically when the fan is fully inserted into the chassis.
6. Secure the fan assembly in position by tightening the thumbscrews (turning them
clockwise).
7. Replace the front bezel.
Replacing a fan
Chapter 5: Replacing server components
Hitachi NAS Platform Series 5000 Hardware Reference
43