180
(2) Reset
Table 7-5 R e s e t
I t e m
Symbol
Min
M a x
U n i t
T e s t
Conditions N o t e s
RESET
Low Pulse Width
t
RESW
40
—
t
c y c 1
Figure 7-5
RESET
Uncertain Time
of Acceptance 1
t
RES1
3
—
ns
RESET
Uncertain Time
of Acceptance 2
t
RES2
5
—
ns
DCLK
Rise Delay Time
From CLK1
t
DCRD
—
30
ns
DCLK
Fall Delay Time From
CLK1
t
DCFD1
—
30
ns
DOT = 1
DCLK
Fall Delay Time From
CLK1
t
DCFD0
—
30
ns
DOT = 0
FCLK Rise Delay Time From
CLK1
t
FCRD
—
30
ns
FCLK Fall Delay Time From
CLK1
t
FCFD
—
30
ns
DCLK
Cycle Time
t
cyc D
2t
cyc1
2t
cyc1
ns
DOT = 1
DCLK
Cycle Time
t
cyc D
1t
cyc1
1t
cyc1
ns
DOT = 0
Summary of Contents for HD64411 Q2