Deskstar 7K80 Hard Disk Drive Specification
110
e. The host reads one sector (or block) of data via the Data Register.
f. The device sets DRQ = 0 after the sector (or block) has been transferred to the host.
4. For the Read Long command:
a. The device sets BSY = 1 and prepares for data transfer.
b. When the sector of data is available for transfer to the host, the device sets BSY = 0 and DRQ=1 and
interrupts the host.
c. In response to the interrupt, the host reads the Status Register.
d. The device clears the interrupt in response to the Status Register being read.
e. The host reads the sector of data including ECC bytes via the Data Register.
f. The device sets DRQ = 0 after the sector has been transferred to the host.
The Read Multiple command transfers one block of data for each interrupt. The other commands transfer one sec-
tor of data for each interrupt.
Note that the status data for a sector of data is available in the Status Register
before
the sector is transferred to the
host.
If the device detects an invalid parameter, then it will abort the command by setting BSY = 0, ERR = 1, ABT = 1,
and interrupting the host.
If an error occurs, the device will set BSY = 0, ERR = 1, and DRQ = 1. The device will then store the error status
in the Error Register and interrupt the host. The registers will contain the location of the sector in error. The error
location will be reported using CHS mode or LBA mode. The mode is decided by the mode select bit (bit 6) of the
Device/Head register upon issuing the command.
If an Uncorrectable Data Error (UNC = 1) occurs, the defective data will be transferred from the media to the sector
buffer and will be available for transfer to the host at the host's option. In case of a Read Multiple command, the
host should complete transfer of the block which includes the error from the sector buffer and terminate whatever
type of error that occurred.
All data transfers to the host through the Data Register are 16 bits except for the ECC bytes which are 8 bits.
11.2 PIO Data Out Commands
The following are Data Out commands:
•
Device Configuration SET
•
Format Track
•
Security Disable Password
•
Security Erase Unit
•
Security Set Password
•
Security Unlock
•
Set Max Set Password
•
Set Max Unlock
•
S.M.A.R.T. Write log sector
•
Write Buffer
•
Write Log Ext
•
Write Long
•
Write Multiple
Summary of Contents for Deskstar 7K80
Page 2: ......
Page 18: ...Deskstar 7K80 Hard Disk Drive Specification 14 ...
Page 20: ...Deskstar 7K80 Hard Disk Drive Specification 16 ...
Page 21: ...Deskstar 7K80 Hard Disk Drive specification 17 Part 1 Functional specification ...
Page 22: ...Deskstar 7K80 Hard Disk Drive Specification 18 ...
Page 24: ...Deskstar 7K80 Hard Disk Drive Specification 20 ...
Page 34: ...Deskstar 7K80 Hard Disk Drive Specification 30 ...
Page 36: ...Deskstar 7K80 Hard Disk Drive Specification 32 ...
Page 55: ...Deskstar 7K80 Hard Disk Drive Specification 51 Part 2 Interface specification ...
Page 56: ...Deskstar 7K80 Hard Disk Drive Specification 52 ...
Page 76: ...Deskstar 7K80 Hard Disk Drive Specification 72 ...
Page 84: ...Deskstar 7K80 Hard Disk Drive Specification 80 ...
Page 118: ...Deskstar 7K80 Hard Disk Drive Specification 114 ...
Page 250: ...Deskstar 7K80 Hard Disk Drive Specification 246 ...