![Hitachi D 10VJ Technical Data And Service Manual Download Page 26](http://html.mh-extra.com/html/hitachi/d-10vj/d-10vj_technical-data-and-service-manual_140981026.webp)
--- 23 ---
8-5. Insulation Tests
On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength: AC 4,000 V/1 minute, with no abnormalities 220 V --- 240 V (and 110 V for U.K. products)
AC 2,500 V/1 minute, with no abnormalities 110 V --- 127 V (except U.K. products)
8-6. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) Max.
1.6
230
1.5
240
1.7
220
Voltage (V)
Current (A) Max.
1.5
240
3.5
110
1.6
230
Model D 13VB3
Model D 13VH
Voltage (V)
Current (A) Max.
1.6
230
1.5
240
1.7
220
Model D 10VJ
3.5
110