4
2.6
Winder
Remove the cover, as described previously and remove the winder
from the bottom case.
To reassemble, put the winder in the slot in the casing and put the
cables into the grips on top of the motor housing.
2.7 Removing and Replacing the Motor
Remove the cover of the vacuum cleaner as previously described,
then
remove the winder, unscrew the four screws holding the motor cover.
Remove the cover, then the motor.
To reassemble,
replace the connections
,
mount dampers,
fit front
circular seal
and the motor in its housing.
Check that the mounting of
the
dampers and seal
are correct
and then replace motor. When
reassembling the motor housing, ensure that the motor cables are not
trapped but are fed through the two holes in the housing.
3. Circuit Diagrams
4.
Constructional Diagrams
5.
Accessories for Hitachi CV-600/610/710
6.
List of spare parts for Hitachi CV-600
7.
List of spare parts for Hitachi CV-610
8.
List of spare parts for Hitachi CV-710
Final Tests
1.
After re-assembly, run the vacuum cleaner for at least 15
minutes without joining the hose to the main body and ensure
that there is no abnormal vibration
2. Measure the insulation resistance between the power supply
plug and metal surfaces with a 500V DC insulation resistance
and ensure that the insulation resistance is not less than 10M
ohm.
9.
10.
Accessories Parts List
Final Tests
10.
Removing and Replacing the Supply Lead