25
Connection to the control signal terminal (continued)
Control data table
Item
MOUSE
COMMUNICATE
POWER
ZOOM
FOCUS
MIRROR
INPUT
VIDEO SYSTEM
VOLUME
MUTE
BRIGHT
CONTRAST
COLOR
TINT
SHARPNESS
H.PHASE
H.POSIT
H.SIZE
V.POSIT
BLANK
REVEAL
Caution
If computer sends the undefined command code or data code, Projector can not guarantee
operation.
Data code
00h=stop mouse emulation. 01
∼
7Fh=start mouse emulation
0Xh=8N1
1Xh=7N1
X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps
1Eh=Power off (Standby mode), 1Fh=Power on
01-3Fh=Zoom +, 41-7Fh=Zoom- 01, 04 (up)
∼
3F, 7F (down)
01-3Fh=Focus +, 41-7Fh=Focus- 01, 04 (short)
∼
3F, 7F (long)
00h=Normal, 01h=H:Invert, 02h=V:Invert, 03h=H & V:Invert
11h=VIDEO1, 12h=VIDEO2, 21h=RGB1, 22h=RGB2
00h 00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4.43
00h 02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL
00h (min)
∼
7Fh (max)
00h=Mute off, 01h=Mute on
00h 00h 00h (dark)
∼
00h 00h 7Fh (brite)
00h 00h 00h (lower)
∼
00h 00h 7Fh (higher)
00h 00h 20h (less)
∼
00h 00h 60h (more)
00h 00h 2Eh (red)
∼
00h 00h 52h (green)
00h 00h 00h (soft)
∼
00h 00h 64h (sharp)
00h 00h 00h
∼
00h 00h 1Fh
00h 00h 52h 00h (left)
∼
00h 00h 54h 04h (right)
00h 00h 00h 06h (narrow)
∼
00h 00h 48h 0Bh (wide)
00h 00h 06h 00h (down)
∼
00h 00h 50h 05h (up)
0Xh=Blank off
1Xh=Blank on
bit0 0=Blue off, 1=Blue on,
bit1 0=Green off,
1=Green on
bit2 0=Red off, 1=Red on,
bit3 0=Not change, 1=Change
X1h=Reveal down, X4h=Reveal right, X=0 (slow)
∼
7 (fast)
Command is consisted of 2 command bytes and following data bytes.
1-st byte indicates the kinds of commands and the length of command.
‘0xH’ : Error-reply
Projector sends to computer.
‘1xH’ : Command reply
Projector sends to computer.
‘2xH’ : Ask command
Computer sends to Projector.
‘3xH’ : Set command
Computer sends to Projector.
‘4xH’ : Default set command
Computer sends to Projector.
‘5xH’ — ‘FxH’ : Reserved
‘x’ indicates the length of data bytes.
2-nd byte indicates the command code ‘yy’ as command table.
Data table shows the data byte.