– 7 –
Message
T
able
On-screen display
The following messages are displayed on the screen.
MESSAGE
Action
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN
OFF AFTER * Hr.
The total lamp service time will exceed the lamp replacement time in * hours.
The lamp will go off automatically when the lamp replacement time is exceeded.
Replace with a new lamp before that. *1
The asterisk (*) indicates the number of hours remaining before the lamp goes
off automatically.
Blinking of
CHANGE THE LAMP
The total lamp service time has exceeded the lamp replacement time. The lamp
will go off automatically about 10 minutes after it starts blinking. Replace with a
new lamp.*2
NO INPUT IS DETECTED
Signal is hot input.
SYNC IS OUT OF RANGE
The horizontal frequency of the input signal exceeds the range of the projector, it
cannot be displayed.
Indicator display
The ON indicator, LAMP indicator and TEMP indicator will light or blink in the following cases.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
The lamp has been in service for long. Replacement with a new lamp is
recommended. The lamp will go off automatically when the lamp replacement
time is exceeded. *1
*1 This message are not displayed after 3 minutes.
But this message are displayed when you turn on the power again.
*2 It is possible to again turn on the power, however the power will go off after about 10 minutes.
ON indicator
LAMP indicator TEMP indicator
Meaning
Remedy
Lights orange
Goes off
Goes off
Standby mode
Blinks green
Goes off
Goes off
During warming up
Lights green
Goes off
Goes off
During operation *1
Blinks orange
Goes off
Goes off
During cooling down
Lights red
Lights red
Goes off
Lamp cannot light *2
Cool projector by power off for 45
minutes.
If the indicator is still it, lamp may be
defective. Replace.
Lights red
Blinks red
Goes off
Lamp is not inserted or the
lamp door open
Securely insert the lamp or close the
lamp door.
Lights red
Goes off
Blinks red
Cooling fan accidented
Replace fan.
Blinks red
Blinks red
Goes off
The total lamp service time has
exceeded the lamp
replacement time.
Replace lamp and reset the
accumulated lamp operation time.
Summary of Contents for CP-X940E
Page 26: ... 26 8 Block Diagram ...
Page 29: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y COLOR ...
Page 30: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DIGITAL AUTO SETUP IC ...
Page 31: ...to POWER UNIT PWB ass y SIGNAL B C E D D E C B A A 6 5 4 3 2 1 ...
Page 32: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y VIDEO ...
Page 33: ... 33 A B C D E A B C D E 1 2 3 4 5 6 POWER UNIT CIRCUIT 1 2 ...
Page 34: ... 34 A B C D E A B C D E 1 2 3 4 5 6 POWER UNIT CIRCUIT 2 2 ...
Page 35: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 1 9 ...
Page 36: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 2 9 ...
Page 37: ...B C E D D E C B A A 6 5 4 3 2 1 DAGND BLOCK PWB ass y DRIVE 3 9 ...
Page 38: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 4 9 ...
Page 39: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 5 9 ...
Page 40: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 6 9 ...
Page 41: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 7 9 ...
Page 42: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y DRIVE 8 9 ...
Page 43: ...PWB ass y DRIVE 9 9 43 ...
Page 44: ...B C E D D E C B A A 6 5 4 3 2 1 PWB ass y RGB 1 3 ...
Page 45: ... female female female B C E D D E C B A A 6 5 4 3 2 1 B R S B R S PWB ass y RGB 2 3 ...
Page 46: ... male SERIAL MOUSE RS232C B C E D D E C B A A 6 5 4 3 2 1 PWB ass y RGB 3 3 ...
Page 49: ... 49 3X8 3X8 3X12 3X8 23 22 26 31 38 30 24 35 17 13 5 3 14 12 40 41 3X8 43 ...
Page 50: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...