Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the
appropriate measures.

Table 10. Indicators Message

POWER

indicator

LAMP

indicator

TEMP

indicator

Contents

Lights

orange

Turns off Turns off

The Standby mode has been set.

Blinks

green

Turns off Turns off

Warming up. Please wait.

Lights

green

Turns off Turns off

ON. Normal operation possible.

Blinks

orange

Turns off Turns off

Cooling. Please wait.

Blinks red

-

-

Cooling. Please wait. 
The error is found. Take the appropriate measures when the
POWER indicator ceases blinking 

Blinks

/Lights red

Lights

red

Turns off

Lamp is not lit.
The interior of the equipment may be too hot. Switch power OFF,
wait 20 minutes until the equipment cools, and check whether the
ventilation openings are  blocked, whether the air filter is dirty, or
whether the ambient temperature exceeds 35 °C. And switch
power ON again. Replace the lamp if the same problem occurs.

Blinks

/Lights red

Blinks

red

Turns off

Lamp or lamp cover is not found, or hasn’t been fitted in correctly.
Switch power OFF, and wait for 45 minutes until the equipment
cools. Check fitting of the lamp and lamp cover, and switch power
ON again. Contact your dealer if the same problem occurs again.

Blinks

/Lights red

Turns off

Blinks

red

The cooling fan is not operating.
Switch power OFF, and wait for 20 minutes until the equipment
cools. Check for foreign matters in the fan, and switch power ON
again. Contact your dealer if the same problem occurs again.

Blinks

/Lights red

Turns off Lights red

The interior of the equipment is too hot. 

*

2)

Switch power OFF, and wait for 20 minutes until the equipment
cools. Check whether the ventilation openings are  blocked,
whether the air filter is dirty, or whether the ambient temperature
exceeds 35 °C. Then switch power ON again. Contact your dealer if
the same problem occurs again.

Lights

green

Blinks

red

Blinks

red

The interior of the equipment is too cool.
Check whether the ambient temperature is below 0°C. Contact your
dealer if the same problem occurs when the ambient temperature is
0~35°C.

*2) When the internal temperature becomes excessive power is switched OFF

automatically for safety reasons, and the indicator is extinguished. Set the power switch to [

O

] and

wait for 20 minutes until the equipment has cooled sufficiently.

NOTE

01CP-X380W  01.11.19 11:54 AM  ページ 21

Summary of Contents for CP-X380W

Page 1: ...ENGLISH Liquid Crystal Projector CP X380W USER S MANUAL Please read this user s manual thoroughly to ensure correct usage through understanding ...

Page 2: ...ignal Menu 16 Table 9 OSD Message 20 Table 10 Indicator Message 21 Table 11 Symptom 22 Table 12 Specifications 23 For TECHNICAL and REGULATORY NOTICE see the end of this manual The information in this manual is subject to change without notice The manufacturer assumes no responsibility for any errors that may appear in this manual The reproduction transmission or use of this document or contents i...

Page 3: ...sen Sie diese Bedienungsanleitung zugunsten der korrekten Bedienung aufmerksam MANUEL D UTILISATION Nous vous recommandons de lire attentivement ce manuel pour bien assimiler le fonctionnement de l appareil MANUALE D ISTRUZIONI Vi preghiamo voler leggere attentamente il manuale d sitruzioni in modo tale da poter comprendere quanto riportato ai fini di un corretto utilizzo del proiettore MANUAL DE ...

Page 4: ... Air Filter and Intake for the Cooling Fan Rear Foot Adjuster INPUT Button LAMP Indicator TEMP Indicator POWER Indicator RESET Button MENU Button Ventilation Openings exhaust REAR RIGHT VIEW OF THE PROJECTOR Terminal Panel Refer below TERMINAL PANEL S VIDEO Terminal COMPONENT VIDEO Y Terminal CB PB Terminal CR PR Terminal VIDEO IN Terminal AUDIO IN R Terminal AUDIO IN L Terminal AUDIO IN 1 Termina...

Page 5: ...on Used to operate the mouse shift function MAGNIFY Button BLANK Button RGB Button MOUSE RIGHT Button Used to click the right mouse button RESET Button Used to click the right mouse button FREEZE Button MUTE Button KEYSTONE Button VOLUME Button These functions works when the mouse control function is activated Remember the POSITION BLANK ON and MENU ON functions disable the mouse control function ...

Page 6: ...ly oriented as indicated in the remote control transmitter Incorrect orientation could cause battery cracking or leakage which could result in personal injury or pollution of the surrounding environment When you dispose the battery you should obey the law in the relative area or country Keep the battery away from children and pets When not to be used for an extended period remove the batteries fro...

Page 7: ...e screen 10 Table 1 Installation Reference a CAUTION Install the projector in a suitable environment according to instructions of the accompanying manual SAFETY INSTRUCTIONS and this manual When you fix this unit with a metal tool and the like you must connect it with ground wire otherwise fire or electric shock can result Connect the ground terminal of AC inlet of this unit with the ground termin...

Page 8: ...ables which are included with the projector or specified Cabling Refer to the table below for connecting each terminal of the projector to each device Table 2 Cabling Function Terminal Cable RGB input RGB IN 1 Accessory RGB cable or optional RGB cable with D sub 15 pin shrink jack and inch thread screws RGB IN 2 RGB output RGB OUT Audio input from the computer AUDIO IN 1 interlocked with RGB IN 1 ...

Page 9: ...including a computer and display and an operating system This projector is recognized as a plug play monitor Use the standard display drivers Plug play may not operate by the computer to connect Use the RGB IN 2 terminal if plug play does not operate correctly NOTE NOTE ENGLISH 8 I I I IN N N NS S S ST T T TA A A AL L L LL L L LA A A AT T T TI I I IO O O ON N N N c c c co o o on n n nt t t ti i i ...

Page 10: ...t while the POWER indicator is blinking 2 The system assumes the Standby mode when cooling is complete and the POWER indicator ceases blinking and changes to orange Check that the indicator is orange and set the power switch to O 3 The POWER indicator is extinguished when power is off Do not forget to close the lens door STANDBY ON LASER BLANK RGB VIDEO AUTO MENU MENU SELECT KEYSTONE RESET FREEZE ...

Page 11: ...ty the icon is extinguished and the POSITION mode is cleared automatically and buttons may operate as the mouse control button Refer to page 4 RESET Initialise Each Item Select an item and press the RESET button Initialise Position Adjustment Press the RESET button and the POSITION mode This function is valid only when RGB signal is input Valid except for the VOLUME LANGUAGE and H PHASE The RESET ...

Page 12: ... Stop Press the MENU button The menu display is terminated automatically after approximately 10 seconds of inactivity MENU SELECT Select Menu Type Press the MENU SELECT button Allows the user to select the normal menu or the single menu Only the selected item is displayed on the single menu and other items are displayed with the and buttons as with the normal menu Valid only when the Setup menu is...

Page 13: ...SE COLOR BAL R COLOR BAL B ASPECT 0 1 1 0 0 0 SETUP INPUT OPT IMAGE Table 4 Setup Menu Item Description RGB VIDEO S VIDEO COMPONENT 480i 575i 480P 720P 1080i BRIGHT Dark Light CONTRAST Weak Strong V POSIT Down Up H POSIT Left Right H PHASE Left Right Adjust to eliminate flicker H SIZE Small Large The image may not be displayed correctly if the horizontal size is excessive In such cases press the R...

Page 14: ...tly with some input signals Pressing the AUTO button in this case may correct this problem This function is the same as for the AUTO function in Basic operation RGB Displays RGB Input Frequency Displays the horizontal and vertical sync signal frequencies for RGB input Valid only at RGB input VIDEO Select Video Signal Type Select the signal type with the and buttons Select NTSC PAL SECAM NTSC4 43 M...

Page 15: ...een Color Select color with the button The image is cleared and the entire screen is displayed in the selected color when BLANK mode is set with BLANK ON or when there is no signal for 5 minutes MIRROR Select Mirror Status Select mirror status with button START UP Setup Initial Screen Display Select TURN ON with the button Clear Initial Screen Display Select TURN OFF with the button Note that if T...

Page 16: ...O OFF Set AUTO OFF Set 1 99 minutes with the button The system automatically enters the standby mode when a signal is not received for the set time Clear AUTO OFF Select STOP 0 min with the button When STOP is selected the system does not enter the standby mode even if no signal is received SYNC ON G SYNC ON G Valid Select TURN ON with the button SYNC ON G Invalid Select TURN OFF with the button M...

Page 17: ...cted color MIRROR Select Mirror Status Select the mirror status with the button START UP Setup Initial Screen Display Select the TURN ON with the button Clear Initial Screen Display Select the TURN OFF with the button Note that if TURN OFF is selected the blank screen is displayed in blue when there is no signal MENU COLOR Select Menu Background Color Select the color with the button LANGUAGE Sele...

Page 18: ...e Before replacing the lamp switch power OFF wait approximately 20 minutes and switch power ON again If the LAMP indicator is still red replace the lamp NOTE WARNING For disposal of used lamp treat according to the instruction of community authorities Since the lamp is made of glass do not apply shock to it and do not scratch it Also do not use old lamp This could also cause explosion of the lamp ...

Page 19: ...the Lamp Timer Reset the lamp timer after replacing the lamp When the lamp has been replaced after the LAMP indicator is red or the CHANGE THE LAMP message is displayed complete the following operation within ten minutes of switching power ON The power will be turned off automatically in over 10 minutes 1 Switch power ON and press the RESET button for approximately three seconds The LAMP xxxx hr m...

Page 20: ...th CAUTION Switch power OFF and remove the power cord from the power outlet before beginning maintenance work Please read the separate SAFETY INSTRUCTIONS thoroughly to ensure that maintenance is performed correctly Do not use detergents or chemicals other than those noted above e g benzene or thinners Do not use cleaning sprays Do not rub with hard materials or tap the equipment CAUTION Switch po...

Page 21: ...reset the lamp timer after replacing the lamp CHANGE THE LAMP AFTER REPLACING LAMP RESET THE LAMP TIME THE POWER WILL TURN OFF AFTER 0 hr The usage time of lamp is about to reach Power will be switched OFF in a few minutes 2 Switch power OFF immediately and replace the lamp as shown in P 17 18 Lamp Always reset the lamp timer after replacing the lamp NO INPUT IS DETECTED ON No input signal found C...

Page 22: ...ts red Blinks red Turns off Lamp or lamp cover is not found or hasn t been fitted in correctly Switch power OFF and wait for 45 minutes until the equipment cools Check fitting of the lamp and lamp cover and switch power ON again Contact your dealer if the same problem occurs again Blinks Lights red Turns off Blinks red The cooling fan is not operating Switch power OFF and wait for 20 minutes until...

Page 23: ...t but no audio The projector is not correctly connected Connect correctly 7 8 The volume is set to minimum Press VOLUME on the remote control or display the menu screen and adjust the volume 11 15 Mute is turned on Press the MUTE button 11 Audio is present but no video The projector is not correctly connected Connect correctly 7 8 The brightness adjustment knob is rotated fully clockwise Select BR...

Page 24: ...nc TTL level D sub 15 pin shrink jack 2 AUDIO IN 1 200mVrms 50 kΩ max 3 0Vp p Stereo mini jack 2 Video signal input VIDEO IN 1 0Vp p 75Ω terminator RCA jack S VIDEO IN Brightness signal 1 0Vp p 75Ω terminator Color signal 0 286Vp p NTSC burst signal 75Ω terminator 0 3Vp p PAL SECAM burst signal 75Ω terminator Mini DIN 4 pin jack COMPONENT VIDEO Y 1 0 Vp p 75 Ω Terminator Positive CB CR 0 7 Vp p 75...

Page 25: ...TER SERVICE If a problem occurs with the equipment first refer to the P 20 TROUBLESHOOTING section and run through the suggested checks If this does not resolve the problem contact your dealer or service company They will tell you what warranty condition is applied ...

Page 26: ...8 Ground Blue 14 Vertical sync TECHNICAL 1 TECHNICAL TECHNICAL TECHNICAL Dimension Diagram 298 94 6 54 228 241 5 76 76 5 Unit mm 2 Mini Din 4 pin Connector S VIDEO Pin No Signal 1 Color 0 286Vp p NTSC burst signal 75Ω terminator 0 3Vp p PAL SECAM burst signal 75Ω terminator 2 Brightness 1 0Vp p 75Ω terminator 3 Ground 4 Ground Signal Connector Pin Assignment 1 D sub 15 pin Shrink Connector RGB IN ...

Page 27: ...fH kHz fV Hz Rating Signal mode Display mode 640 350 37 9 85 1 VESA VGA 1 Zoom in 640 400 37 9 85 1 VESA VGA 2 Zoom in 720 400 37 9 85 0 VESA TEXT Zoom in 640 480 31 5 59 9 VESA VGA 60Hz Zoom in 640 480 35 0 66 7 Mac13 mode Zoom in 640 480 37 9 72 8 VESA VGA 72Hz Zoom in 640 480 37 5 75 0 VESA VGA 75Hz Zoom in 640 480 43 3 85 0 VESA VGA 85Hz Zoom in 800 600 35 2 56 3 VESA SVGA 56Hz 800 600 37 9 60...

Page 28: ... 17 8 1 6 SVGA 56Hz 2 0 3 6 22 2 0 7 SVGA 60Hz 3 2 2 2 20 0 1 0 SVGA 72Hz 2 4 1 3 16 0 1 1 SVGA 75Hz 1 6 3 2 16 2 0 3 SVGA 85Hz 1 1 2 7 14 2 0 6 Mac 16 mode 1 1 3 9 14 5 0 6 XGA 60Hz 2 1 2 5 15 8 0 4 XGA 70Hz 1 8 1 9 13 7 0 3 XGA 75Hz 1 2 2 2 13 0 0 2 XGA 85Hz 1 0 2 2 10 8 0 5 1152 864 75Hz 1 2 2 4 10 7 0 6 1280 960 60Hz 1 0 2 9 11 9 0 9 1280 1024 60Hz 1 0 2 3 11 9 0 4 1280 1024 75Hz 1 1 1 8 9 5 0...

Page 29: ...th a suitable commercially available USB cable Consult your dealer to get the cable if you need 2 Start the mouse function Refer to the descriptions of DISC PAD and MOUSE RIGHT button of page 4 Before connecting read the instruction manuals of the devices to be connected In the case of notebook type computers with an internal pointing device the mouse control function will not work unless the inte...

Page 30: ...B Mouse 2 1 4 3 6 5 2 1 4 3 8 7 10 9 12 11 14 13 15 RTS GND 5V ADB GND 5V POWER ON DATA 2 1 4 3 Mouse jack Mini DIN 4 pin Projector Computer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 CONTROL Terminal D sub 15 pin shrink jack Serial Mouse 2 1 4 3 6 5 2 1 4 3 6 5 8 7 10 9 8 7 9 12 11 14 13 15 RI CD RD TD DTR GND DSR CTS RTS RTS GND SEL0 TD 2 1 4 3 6 5 8 9 7 Mouse jack D sub 9 pin Projector Computer 1 2 3 ...

Page 31: ... 4 5 6 7 8 9 CD RD TD DTR GND DSR RTS DTS RI 1 2 3 4 5 6 7 8 9 RS 232C jack D sub 9 pin Projector Computer Communications setting 19200bps 8N1 1 Protocol Consist of header 7 bytes command data 6 bytes 2 Header BE EF 03 06 00 CRC_low CRC_high CRC_low Lower byte of CRC flag for command data CRC_high Upper byte of CRC flag for command data 3 Command data byte_0 byte_1 byte_2 byte_3 byte_4 byte_5 Acti...

Page 32: ...projector returns the response code 06H to the computer Decreasing the projector setting value Decrement command 1 The computer sends the decrement code Header Command data 05H 00H type 2 bytes 00H 00H to the projector 2 The projector decreases the setting value on the above setting code 3 The projector returns the response code 06H to the computer When a command sent by the projector cannot be un...

Page 33: ...0 00 Orange BE EF 03 06 00 EF D2 01 00 03 30 01 00 Green BE EF 03 06 00 1F D2 01 00 03 30 02 00 Blue BE EF 03 06 00 8F D3 01 00 03 30 03 00 Purple BE EF 03 06 00 BF D1 01 00 03 30 04 00 Transparent BE EF 03 06 00 2F D0 01 00 03 30 05 00 Gray BE EF 03 06 00 DF D0 01 00 03 30 06 00 Get BE EF 03 06 00 4C D3 02 00 03 30 00 00 Startup Set Turn ON BE EF 03 06 00 0B D2 01 00 04 30 00 00 Turn OFF BE EF 03...

Page 34: ...C D1 06 00 0B 70 00 00 Keystone_V Reset Execute BE EF 03 06 00 08 D0 06 00 0C 70 00 00 Auto Execute BE EF 03 06 00 91 D0 06 00 0A 20 00 00 Blank on off Set off BE EF 03 06 00 FB D8 01 00 20 30 00 00 on BE EF 03 06 00 6B D9 01 00 20 30 01 00 Get BE EF 03 06 00 C8 D8 02 00 20 30 00 00 Error Status Get BE EF 03 06 00 D9 D8 02 00 20 60 00 00 Example of Return 00 00 01 00 02 00 03 00 Normal Cover error...

Page 35: ...tone_V Get BE EF 03 06 00 B9 D3 02 00 07 20 00 00 Increment BE EF 03 06 00 DF D3 04 00 07 20 00 00 Decrement BE EF 03 06 00 0E D2 05 00 07 20 00 00 Aspect Set 4 3 Full BE EF 03 06 00 9E D0 01 00 08 20 00 00 16 9 BE EF 03 06 00 0E D1 01 00 08 20 01 00 Small BE EF 03 06 00 FE D1 01 00 08 20 02 00 Get BE EF 03 06 00 AD D0 02 00 08 20 00 00 Display Position at 16 9 or Small Set Default BE EF 03 06 00 ...

Page 36: ...E EF 03 06 00 FE 72 05 00 03 22 00 00 Video Format Set Auto BE EF 03 06 00 9E 75 01 00 00 22 0A 00 NTSC BE EF 03 06 00 FE 71 01 00 00 22 04 00 PAL BE EF 03 06 00 6E 70 01 00 00 22 05 00 SECAM BE EF 03 06 00 6E 75 01 00 00 22 09 00 NTSC 4 43 BE EF 03 06 00 5E 72 01 00 00 22 02 00 M PAL BE EF 03 06 00 FE 74 01 00 00 22 08 00 N PAL BE EF 03 06 00 0E 71 01 00 00 22 07 00 Get BE EF 03 06 00 0D 73 02 00...

Page 37: ...3 06 00 08 23 02 00 00 33 00 00 GAMMA Set NORMAL BE EF 03 06 00 C7 F0 01 00 A1 30 00 00 CINEMA BE EF 03 06 00 57 F1 01 00 A1 30 01 00 DYNAMIC BE EF 03 06 00 A7 F1 01 00 A1 30 02 00 Get BE EF 03 06 00 F4 F0 02 00 A1 30 00 00 COLOR TEMP Set NORMAL BE EF 03 06 00 FB F5 01 00 B0 30 00 00 LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00 Get BE EF 03 06 00 C8 F5 02 00 B0 30 00 00 TECHNICAL 12 T T T TE E E EC ...

Page 38: ...ne or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help INSTRUCTIONS TO USERS This equipment complies with the requirements of FCC Federal Communi...

Page 39: ......

Page 40: ...s Systems Nordic Kuldyssen 13 DK 2630 Tåstrup Denmark Tel 45 43 99 9200 Fax 45 43 99 9392 Hitachi Business Systems Nordic Tapiolan Keskustorni 11 Krs Fin 02100 Espoo Finland Tel 358 9 3487 1188 Fax 358 9 455 2152 Hitachi France Immeuble Ariane 18 Rue Grange Dame Rose B P 134 78148 Velizy Cedex France Tel 33 1 34630542 Fax 33 1 34650761 Hitachi Sales Iberica S A Gran Via Carlos 111 101 1 1 08028 Ba...

Reviews: