When SNMP is enabled, the projector is able to send Failure/Warning Alerts to a
VSHFL¿HG3&
• It is recommended that SNMP functions be carried out by a network
administrator.
• SNMP management software must be installed on the computer to monitor
the projector via SNMP.
NOTE
SNMP settings
&RQ¿JXUHWKHIROORZLQJLWHPVYLDDZHEEURZVHUWRXVH6103
Example: If the IP address of the projector is set to 192.168.1.10:
$1HWZRUN5HVWDUWLVUHTXLUHGDIWHUWKH61037UDSFRQ¿JXUDWLRQ
settings have been changed. Click
[Network Restart]
DQGFRQ¿JXUHWKH
following items.
NOTE
(
25
)
5) Click
[Security Settings]
on the main menu.
6) Click
[SNMP]
and set the Community Name on the screen that is displayed.
• A Network Restart is required after the Community Name has been
changed.
• Click
[Network Restart]
DQGFRQ¿JXUHWKHIROORZLQJLWHPV
NOTE
&RQ¿JXUHWKHVHWWLQJVIRU7UDSWUDQVPLVVLRQRI)DLOXUHV:DUQLQJV&OLFN
[Alert Settings]
on the main menu and select the Failure/Warning item to be
FRQ¿JXUHG
8) Click the
[Enable]
check box to send out the SNMP trap for Failures/Warnings.
Clear the
[Enable]
check box when SNMP trap transmission is not required.
9) Click the
[Apply]
button to save the settings.
1) Enter
[http://192.168.1.10]
into the address bar of the web browser.
2) Enter the Administrator ID and Password and click
[Logon
].
3) Click
[Port Settings]
on the main menu.
4) Click the
[Enable]
check box to open the SNMP Port.
Set the IP address to send the SNMP Trap to when a Failure/Warning occurs.
4. Utilize projector – Advanced -
4.5 Projector management via SNMP