9
Names
Operation Type
Header
Command Data
CRC
Action
Type
Setting Code
Power
Set
Turn off
BE EF
03
06 00
2A D3
01 00
00 60
00 00
Turn on
BE EF
03
06 00
BA D2
01 00
00 60
01 00
Get
BE EF
03
06 00
19 D3
02 00
00 60
00 00
[Example return]
00 00
01 00
02 00
[Off]
[On]
[Cool down]
Input Source
Set
COMPUTER1
BE EF
03
06 00
FE D2
01 00
00 20
00 00
COMPUTER2
BE EF
03
06 00
3E D0
01 00
00 20
04 00
COMPONENT
BE EF
03
06 00
AE D1
01 00
00 20
05 00
S-VIDEO
BE EF
03
06 00
9E D3
01 00
00 20
02 00
VIDEO
BE EF
03
06 00
6E D3
01 00
00 20
01 00
Get
BE EF
03
06 00
CD D2
02 00
00 20
00 00
Error Status
Get
BE EF
03
06 00
D9 D8
02 00
20 60
00 00
[Example return]
00 00
01 00
02 00
03 00
[Normal]
[Cover error]
[Fan error]
[Lamp error]
04 00
05 00
06 00
07 00
>7HPSHUURU@
>$LUÀRZHUURU@
>/DPSWLPHHUURU@
>&ROGHUURU@
08 00
09 00
10 00
[Filter error]
(Filter missing error)
(Inner Sencer error)
(continued on next page)
BRIGHTNESS
Get
BE EF
03
06 00
89 D2
02 00
03 20
00 00
Increment
BE EF
03
06 00
EF D2
04 00
03 20
00 00
Decrement
BE EF
03
06 00
3E D3
05 00
03 20
00 00
BRIGHTNESS Reset
Execute
BE EF
03
06 00
58 D3
06 00
00 70
00 00
CONTRAST
Get
BE EF
03
06 00
FD D3
02 00
04 20
00 00
Increment
BE EF
03
06 00
9B D3
04 00
04 20
00 00
Decrement
BE EF
03
06 00
4A D2
05 00
04 20
00 00
CONTRAST Reset
Execute
BE EF
03
06 00
A4 D2
06 00
01 70
00 00
PICTURE MODE
Set
NORMAL
BE EF
03
06 00
23 F6
01 00
BA 30
00 00
CINEMA
BE EF
03
06 00
B3 F7
01 00
BA 30
01 00
DYNAMIC
BE EF
03
06 00
E3 F4
01 00
BA 30
04 00
BOARD(BLACK)
BE EF
03
06 00
E3 EF
01 00
BA 30
20 00
BOARD(GREEN)
BE EF
03
06 00
73 EE
01 00
BA 30
21 00
WHITEBOARD
BE EF
03
06 00
83 EE
01 00
BA 30
22 00
DAYTIME
BE EF
03
06 00
E3 C7
01 00
BA 30
40 00
Get
BE EF
03
06 00
10 F6
02 00
BA 30
00 00
[Example return]
00 00
01 00
04 00
10 00
[Normal]
[Cinema]
[Dynamic]
[Custom]
20 00
21 00 22 00
40 00
[BOARD(BLACK) ]
[BOARD(GREEN)]
[WHITEBOARD]
[DAY TIME]
GAMMA
Set
#1 DEFAULT
BE EF
03
06 00
07 E9
01 00
A1 30
20 00
#1 CUSTOM
BE EF
03
06 00
07 FD
01 00
A1 30
10 00
#2 DEFAULT
BE EF
03
06 00
97 E8
01 00
A1 30
21 00
#2 CUSTOM
BE EF
03
06 00
97 FC
01 00
A1 30
11 00
#3 DEFAULT
BE EF
03
06 00
67 E8
01 00
A1 30
22 00
#3 CUSTOM
BE EF
03
06 00
67 FC
01 00
A1 30
12 00
#4 DEFAULT
BE EF
03
06 00
F7 E9
01 00
A1 30
23 00
#4 CUSTOM
BE EF
03
06 00
F7 FD
01 00
A1 30
13 00
#5 DEFAULT
BE EF
03
06 00
C7 EB
01 00
A1 30
24 00
#5 CUSTOM
BE EF
03
06 00
C7 FF
01 00
A1 30
14 00
#6 DEFAULT
BE EF
03
06 00
57 EA
01 00
A1 30
25 00
#6 CUSTOM
BE EF
03
06 00
57 FE
01 00
A1 30
15 00
Get
BE EF
03
06 00
F4 F0
02 00
A1 30
00 00
RS-232C Communication (continued)
Summary of Contents for CP-X201
Page 20: ...11 ...
Page 22: ...13 ...
Page 44: ......
Page 75: ...66 6SHFLÀFDWLRQV 6SHFL FDWLRQV FRQWLQXHG XQLW PP ...