27
CP-SX1350(P5SX+)
6-10 Related messages
When the unit's power is ON, messages such as those shown below may be displayed. When any such
message is displayed on the screen, please respond as described below.
Message
Description
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER. (*1)
Lamp usage time is approaching 2000 hours. (*2)
Preparation of a new lamp, and an early lamp change is
recommended. After you have changed the lamp, please
be sure to reset the lamp timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER ** hr. (*1)
Lamp usage time is approaching 2000 hours. (*2)
A lamp change within ** hours is recommended.
When lamp usage reaches 2000 hours, the power will
automatically be turned OFF. Please change the lamp by
referring to the "Lamp" section of this manual. After you
have changed the lamp, please be sure to reset the lamp
timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER 0 hr.
As lamp use has reached 2000 hours (*2), the power will
soon be automatically turned OFF.
Please immediately turn the power off, and change the
lamp by referring to the "Lamp" section of this manual.
After you have changed the lamp, please be sure to reset
the lamp timer.
NO INPUT IS DETECTED
ON ***
There is no input signal.
Please confi rm the signal input connection, and the status
of the signal source.
SYNC IS OUT OF RANGE
ON ***
fH
*****kHz
fV
*****Hz
The horizontal or vertical wavelength of the inputted
signal is outside of the response parameters of this unit.
Please confi rm the specs for this unit or the signal source
specs.
REMINDER
***HRS PASSED AFTER THE LAST
FILTER CHECK.
FILTER MAINTENANCE IS
ESSENTIAL TO REMOVE WARNING
MESSAGE, RESET FILTER TIMER.
SEE MANUAL FURTHER INFO.
The time the filter timer has counted has reached the
interval time set by the "FILER MESSAGE" of "SERVICE"
item in the OPTION menu.
Please clear or change the air filter by referring to the
section “Air Filter”. After caring for the air fi lter, please be
sure to reset the fi lter timer.
PLEASE CHECK THAT THE
FILTER HAS BEEN CLEANED.
FAILURE TO CLEAN MAY
RESULT IN DAMAGE TO THE
PROJECTOR.
SEE MANUAL FURTHER INFO.
The internal portion temperature is rising. Please turn the
power OFF, and allow the unit to cool down at least 20
minutes. After the projector has suffi ciently cooled down,
please make confi rmation of the following items, and then
turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
Note:
(*1) • Although this message will be automatically disappeared after around 3 minutes, it will be
reappeared every time the power is turned ON.
(*2) • Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a
lamp will no longer light up, or the lamp will break or burst, etc. This unit is equipped with an automatic shut-
down function, such that the power will automatically be turned OFF when lamp usage time has reached
2,000 hours. Please be aware, however, that among lamp types, there are major differences in product
lifetimes; a lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this
unit.
Summary of Contents for CP-SX1350 P5SX+
Page 38: ...38 CP SX1350 P5SX 8 Disassembly diagram M Meter screw T Tapping screw ...
Page 39: ...39 CP SX1350 P5SX M Meter screw T Tapping screw ...
Page 53: ...53 CP SX1350 P5SX 12 Connector connection diagram Connector connection diagram ...
Page 73: ...PWB assembly SIGNAL 1 P5SX ...
Page 74: ...PWB assembly SIGNAL 2 P5SX ...
Page 75: ...PWB assembly KEYPAD P5SX ...
Page 76: ...PWB assembly DUST SENSOR P5SX ...
Page 78: ...CP SX1350 YKNo 0553E Digital Media Division QR64671 Printed in Japan JE ...