RS-232C Communication / Network command table
36
Names
Operation Type
Header
CRC
Command Data
Action
Type
Setting code
ECO MODE
Set
NORMAL
BE EF
03
06 00
3B 23
01 00
00 33
00 00
ECO
BE EF
03
06 00
AB 22
01 00
00 33
01 00
Get
BE EF
03
06 00
08 23
02 00
00 33
00 00
INSTALLATION
Set
FRONT / DESKTOP
BE EF
03
06 00
C7 D2
01 00
01 30
00 00
REAR / DESKTOP
BE EF
03
06 00
57 D3
01 00
01 30
01 00
REAR / CEILING
BE EF
03
06 00
A7 D3
01 00
01 30
02 00
FRONT / CEILING BE EF
03
06 00
37 D2
01 00
01 30
03 00
Get
BE EF
03
06 00
F4 D2
02 00
01 30
00 00
STANDBY
MODE
Set
NORMAL
BE EF
03
06 00
D6 D2
01 00
01 60
00 00
SAVING
BE EF
03
06 00
46 D3
01 00
01 60
01 00
Get
BE EF
03
06 00
E5 D2
02 00
01 60
00 00
MENU
POSITION V
Get
BE EF
03
06 00
40 D7
02 00
16 30
00 00
Increment
BE EF
03
06 00
26 D7
04 00
16 30
00 00
Decrement
BE EF
03
06 00
F7 D6
05 00
16 30
00 00
MENU
POSITION V
Reset
Execute
BE EF
03
06 00
A8 C7
06 00
44 70
00 00
MENU
POSITION H
Get
BE EF
03
06 00
04 D7
02 00
15 30
00 00
Increment
BE EF
03
06 00
62 D7
04 00
15 30
00 00
Decrement
BE EF
03
06 00
B3 D6
05 00
15 30
00 00
MENU
POSITION H
Reset
Execute
BE EF
03
06 00
DC C6
06 00
43 70
00 00
BLANK
Set
MyScreen
BE EF
03
06 00
FB CA
01 00
00 30
20 00
ORIGINAL
BE EF
03
06 00
FB E2
01 00
00 30
40 00
BLUE
BE EF
03
06 00
CB D3
01 00
00 30
03 00
WHITE
BE EF
03
06 00
6B D0
01 00
00 30
05 00
BLACK
BE EF
03
06 00
9B D0
01 00
00 30
06 00
Get
BE EF
03
06 00
08 D3
02 00
00 30
00 00