background image

Pillar or

thick ply wood.

Plaster board or
thin ply wood, etc.

− 3 −

The wall where the wall-mount unit is to be
installed must be capable of long-term
support of the total load of the plasma display
and wall-mount unit. Measures should also be
taken to ensure sufficient strength to
withstand the force of earthquakes, vibration
and other external forces.

Incorrect installation can cause the plasma display to fall
and cause injury.

Installation on a wooden wall

Always install so that the load is supported by a piller. If the
strength of the piller is insufficient, add reinforcement. Do
not install on plasters or decorative posts.

Installation on a concrete wall

Use commercially available anchors that are capable of
fully supporting the load of the plasma display.

10cm

or more 

10cm

or more 

10cm

or more 

Avoid installing in
locations where the
temperature and
humidity are
excessively high,
and where contact
with water is
possible.

These can result in fire
or electrical shock.

Installation Location

WARNING

CAUTION

Do not install close
to an air-
conditioner intake
or outlet.
Do not install in
locations where
there is excessive
amounts of dust,
oily smoke or
tobacco smoke.

Fire could result.

Do not block the
ventilation holes.
Also provide
sufficient clearance
in regard to the
surroundings to
avoid blocking the
ventilation.

The internal
temperature could
elevate and possibly
result in fire.

Mount only on a
vertical, rigid wall
surface.

The internal
temperature could
elevate and possibly
result in fire.
Injury or damage could
also result from falling.

Model 50 Total load of the (plasma d wall-mount unit) = 52.7kg

Summary of Contents for CMPAK06

Page 1: ...hops To ensure customer safety be sure to design the installation location so that the strength is sufficient to withstand the weight of both the plasma display and the wall mount unit Always use at least two persons for all installations Fully tighten all of the mounting screws as specified in the installation instructions Thank you for purchasing the Hitachi Plasma Display Wall mount Unit To ens...

Page 2: ...play In the cases such as The plasma display is loose and vibrates to an extreme degree Mounting screws or parts are loose or missing failure to take appropriate actions can result in injury Perform the following actions immediately whenever a malfunction occurs Turn off the plasma display power switch Disconnect the power plug from the power outlet Surround the area with rope etc to prevent other...

Page 3: ...able of fully supporting the load of the plasma display 10cm or more 10cm or more 10cm or more Avoid installing in locations where the temperature and humidity are excessively high and where contact with water is possible These can result in fire or electrical shock Installation Location WARNING CAUTION Do not install close to an air conditioner intake or outlet Do not install in locations where t...

Page 4: ...specified places and tighten firmly Failure to do this could cause injury if the plasma display falls Make sure the display fittings and wall mount fittings are firmly engaged Failure to do so could cause the plasma display to fall Do not alter any of the parts And do not use broken parts This could result in injury due to the plasma display falling Always use at least two people to perform the in...

Page 5: ... red triangle Top side of plasma display 7 Fix the bottom of the hardware with the special screws removed at step 1 one on the left and one on the right Special screw M6 5 Attach the wall side hardware to the wall Install the wall side hardware 4 locations symmetrically on the left and right side one at each location from the center of the Because the screws and bolts used to do this are different...

Page 6: ...X 5 133mm 10 188mm 15 241mm 20 291mm Angle setup This installation hardware allows the display to be directed downwards freely at any angle from the vertical to 25ˇ This adjustment must always be done by 2 people Adjust the angle by rotating the screws at the center top and center bottom of the wall side hardware to the left or right Warning If the angle is increased while you are adjusting the an...

Page 7: ...erial Steel sheet Surface treatment Black baked paint Products mounted CMP5000WX 59 6 φ10 5 6 23x10 5 314 239 314 239 33 35 150 150 35 35 714 44 455 555 655 496 740 1368 With side speaker 545 465 232 212 410 143 45 44 573 258 54 43 1218 Without side speaker 98 125 25 ...

Page 8: ...Hitachi Ltd Tokyo Japan Digital Media Division 292 Yohida cho Totsuka ku Yokohama 244 0817 Japan 045 866 6302 ...

Reviews: