9. POWER LINE SURGE TEST (IEC 61000-4-5 SURGE)
9.1 Climatic Condition
The climatic conditions shall be within the following ranges:
9.1.1
9.1.2
9.1.3
9.2.1
9.2.2
9.2.3
9.2.4
9.2.5 Number of tests: at least 5 positive and 5 negative at the selected points.
Repetition rate:at least 1 per minute
Phase shifting:in a range between 0º to 270º versus the AC line phase angle
Polarity:
positive / negative
Short circuit current:
(8 / 20
µ
s)
Open circuit voltage:
(1.2 / 50
µ
s)
Wave-shape of the current surge: (refer to IEC 61000-4-5)
9.2 Test Conditions:
Note: The temperature and relative humidity should be recorded in the test report.
Atmospheric Pressure 86kPa (860mbar) to 106kPa (1060mbar)
Relative Humidity: 10% to 75%
Ambient Temperature: 15
°
C to 35
°
C
9.3
The surge will be applied between lines and between lines and ground.
9.4
If not otherwise specified, the surge to power supply circuits shall be applied synchronized
to the voltage phase at the zero crossing and the peak value of the AC voltage wave.
(Positive and negative)
9.5
The surge voltage for test is from 1KV and increases 1
K
V for each step.
9.6
The recommended severity levels for the surge voltage test is 2.0KV and without any
degradation or loss of function that is not recoverable due to damage of component or
software allowed.
9.7
Display set high-resolution mode, AC input use AC 240V
.
40
Summary of Contents for CML176SXW
Page 22: ...System Block Diagram 3 4 Connector Locations 22 ...
Page 23: ...23 ...
Page 30: ...6 TROUBLESHOOTING 6 1 Main Procedure EP877 878 30 ...
Page 31: ...6 1 1 Power Circuit and Backlights Troubleshooting 31 ...
Page 32: ...6 1 2 Performance Troubleshooting 32 ...
Page 33: ...6 1 3 Function Troubleshooting 33 ...
Page 37: ...7 7 GAP Spec Gap between panel with bezel is 0 mm gap 1 2 mm ES678 E01 37 ...
Page 39: ...WAVESHAPE 39 ...
Page 45: ...Appendix A PCBA ASSEMBLY 45 ...
Page 46: ...46 ...
Page 47: ...FOR HYDIS PANEL EP877 Appendix B DISPLAY UNIT ASSEMBLY ...
Page 48: ...FOR HYDIS PANEL EP878 ...
Page 57: ...Key Circuit Board ...
Page 58: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...