CAUTION for 200 - 240V operation only 

This equipment relies on the protective devices in the building installation for short-circuit and 
over-current protection. Refer to the following table for the suitable number and location of the 
protective devices which should be provided in the building installation. 

 

Informative examples of  

protective devices in single - phase equipment or sub - assemblies

 

 Protection 

against 

Minimum number of 

fuses or circuit - 

breaker poles 

Location 

Case A:  Equipment to be 
connected to POWER SYSTEMS 
with earthed neutral reliably 
identified, except for Case C below. 

Earth faults 

Overcurrent 


Phase conductor 

Either of the two 

conductors 

Case B:  Equipment to be 
connected to any supply, including 
IT POWER SYSTEMS and 
supplies with reversible plugs, 
except for Case C below. 

Earth faults 

Overcurrent 


Both conductors 
Either of the two 

conductors 

Case C:  Equipment to be 
connected to 3-wire power 
systems with earthed neutral 
reliably identified. 

Earth faults 

Overcurrent 


Each phase conductor 
Each phase conductor 

Verify that the protective devices in the building installation meets the conditions in the table prior 
to installing the equipment. 

 

BE CAREFUL OF POWER CORD CONNECTION ! 

Before inserting the plug of the power cord into a receptacle of the correct voltage, check that the 
connection portion of the power cord is clean (with no dust).  Then, insert the plug of power cord 
to a receptacle firmly, otherwise it may cause electrical shock or fire. 

 

REMOVE THE POWER CORD FOR COMPLETE SEPARATION ! 

For complete separation from the power source, remove the power cord from the monitor or from 
the wall outlet. 

 

AVOID FREQUENT POWER ON-OFF SWITCHING ! 

DO NOT repeat OFF and ON in a short period.  It may cause blurred colours or distortion of the 
displayed pattern. 

 

BE CAREFUL OF STATIC ELECTRICITY ON CRT SURFACE ! 

To prevent electrical shock by the static electricity on the CRT surface, disconnect the power cord 
at least 30 SECONDS AFTER turning off the power. 

 

ABOUT CLEANING 

This monitor has a non-glare and anti-electrostatic treatment on the surface of the screen.  Use 
water or alcoholic solvent with soft cloth like gauze to clean the surface of the screen.  
NEVER use abrasive, glass cleaner containing highly concentrated ammonia and strong base 
chemicals since they damage the surface treatment. 
Clean the cabinet and controls with a lightly moistened soft cloth.  
DO NOT use aerosol sprays, solvents or abrasive cleaners.

Summary of Contents for CM721FET

Page 1: ...n the rear of the monitor This monitor is ENERGY STAR compliant when used with a computer equipped with VESA DPMS The ENERGY STAR emblem does not represent EPA endorsement of any product or service As an ENERGY STAR Partner Hitachi Ltd has determined that this product meets the ENERGY STAR guidelines for energy efficiency USER MANUAL MANUEL D UTILISATION BEDIENUNGSANEITUNG MANUAL DE USUARIO MANUAL...

Page 2: ... Features Package Overview Cautions 3 FCC Statement Warning 5 TCO 99 Statement 6 For the Customers in the UK 8 Installation 10 User Controls 11 OSD Function Description 12 OSD Icon Summary 13 Specifications 14 Troubleshooting 15 Monitor ...

Page 3: ... needs Features 19 inch monitor with a large 366 x 274 mm viewable screen for comfortable viewing OSD user controls for easy and accurate adjustment of the screen image Energy Star compliant to reduce power consumption Package Overview Please make sure the following items are in the shipping packing and found in good condition 19 Monitor Power cord Tilt and swivel stand This manual Please save thi...

Page 4: ...olours or distortion of the displayed pattern BE CAREFUL OF GENERATED MAGNETISM After the power has been turned on or DEGAUSS button has been pressed the CRT is demagnetized for approximately 10 seconds This generates a strong magnetic field around the front cover which may affect the data stored on magnetic tape or disks near the front cover Place such magnetic recording equipment and tapes disks...

Page 5: ...ditions in the table prior to installing the equipment BE CAREFUL OF POWER CORD CONNECTION Before inserting the plug of the power cord into a receptacle of the correct voltage check that the connection portion of the power cord is clean with no dust Then insert the plug of power cord to a receptacle firmly otherwise it may cause electrical shock or fire REMOVE THE POWER CORD FOR COMPLETE SEPARATIO...

Page 6: ...shielded power cord must be used 2 ceed the specified level CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Declaration of Conformity According to 47CFR Part 2 and 15 for Class B Personal Computers and Peripherals and or CPU Boards and Power Supplies used With Class B Personal Computers We H I ...

Page 7: ...ntally harmful substances are used both in the products and during their manufacture Since it is not so far possible to satisfactorily recycle the majority of electronics equipment most of these potentially damaging substances sooner or later enter nature There are also other characteristics of a computer such as energy consumption levels that are important from the viewpoints of both the work int...

Page 8: ...r generating layers of certain computer displays Cadmium damages the nervous system and is toxic in high doses The relevant TCO 99 requirement states that batteries the colour generating layers of display screens and the electrical or electronics components must not contain any cadmium Mercury Mercury is sometimes found in batteries relays and switches It damages the nervous system and is toxic in...

Page 9: ...tent person preferably a qualified electrician If there is no alternative to cutting off the mains plug ensure that you dispose of it immediately having first removed the fuse to avoid a possible shock hazard by inadvertent connection to the mains supply WARNING THIS EQUIPMENT MUST BE EARTHED IMPORTANT The wires in the mains lead are coloured in accordance with the following code Green and Yellow ...

Page 10: ... VESA ist ein Warenzeichen der Video Electronics Standard Association einer Organisation ohne Erwerbscharakter ENERGY STAR ist ein Warenzeichen der Environmental Protection Agency EPA NOTA La información contenida en este manual está sujeta a cambios sin previo aviso El fabricante no se responsabiliza de los errores que puedan aparecer en este manual RECONOCIMIENTO DE MARCAS VGA es una marca regis...

Page 11: ...e power connector on the back panel of the monitor then plug the other end into an appropriately grounded electrical outlet that is easily accessible and close to the monitor 3 First turn on the computer then the monitor 4 Adjust the tilt and swivel base for your viewing comfort And now your monitor installation is complete 1 ...

Page 12: ...1 Power Switch 2 Power LED Indicator Turn monitor on and off LED Color State Green On Yellow Sleep 3 Select button 4 Adjustments For selecting OSD functions For adjusting the display parameters in the selected function ...

Page 13: ...ay the OSD menu 2 To select function press the buttons until the function you want is highlighted 3 Use the buttons to increase or decrease the adjustment of this function 4 Select the Exit icon if you want to exit the OSD function then press the button once ...

Page 14: ...nce Adjusts the curve of the entire image left or right Pincushion Adjusts the curve of the left and right sides inward and outward Parallelogram Adjusts the tilt of the display sides to the left or right Trapezoid Adjusts the top and bottom display widths Rotation Adjusts the tilt of the display H Moire Adjusts horizontal moire V Moire Adjusts vertical moire Color Temp Adjusts picture to make vib...

Page 15: ...Scanning Frequency Horizontal KHz 31 95 Vertical Hz 50 120 Max Resolution 1600 x 1200 Signal Cable 15 pin mini D sub Power Consumption 130W Supply 100 240VAC 10 50 60Hz Power Management Complies with EPA Energy Star VESA DPMS Display Modes Preset 12 User 12 Operating Operating Temperature 0 40 C Relative Humidity 10 90 Dimensions L x W x H Including Stand 469 x 452 x 462 mm Weight Unpacked 23 0kgs...

Page 16: ...e protector is turned on if the monitor is plugged into such equipment Problem No display appears on screen Make sure that the computer is turned on Make sure that the signal cable is properly connected to the video adapter port on the PC Problem Display image is either flickering or unstable Make sure that the signal cable is properly connected to the video adapter port on the PC Problem Image is...

Page 17: ... ITALY Tel 39 02 487861 Tel 39 02 38073415 Servizio Clienti Fax 39 02 48786381 2 Email customerservice italy hitachi eu com HITACHI Europe AB Box 77 S 164 94 Kista SWEDEN Tel 46 0 8 562 711 00 Fax 46 0 8 562 711 13 Email csgswe hitachi eu com HITACHI EUROPE S A S Lyon Office B P 45 69671 BRON CEDEX FRANCE Tel 04 72 14 29 70 Fax 04 72 14 29 99 Email france consommateur hitachi eu com HITACHI EUROPE...

Reviews: