13
Symptom
Possible cause
Remedy
Tool suddenly stopped
Tool was overburdened
Get rid of the problem causing the
overburden.
The battery is overheated.
Let the battery cool down.
Battery cannot be installed Attempting to install a battery other than that
speci
fi
ed for the tool.
Please install a multi volt type battery.
2. Charger
Symptom
Possible cause
Remedy
The charge indicator lamp
is rapidly blinking purple,
and battery charging
doesn’t begin.
The battery is not inserted all the way.
Insert the battery
fi
rmly.
There is foreign matter in the battery
terminal or where the battery is attached.
Remove the foreign matter.
The charge indicator lamp
blinks red, and battery
charging doesn’t begin.
The battery is not inserted all the way.
Insert the battery
fi
rmly.
The battery is overheated.
If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Battery usage time is short
even though the battery is
fully charged.
The battery’s life is depleted.
Replace the battery with a new one.
The battery takes a long
time to charge.
The temperature of the battery, the charger,
or the surrounding environment is extremely
low.
Charge the battery indoors or in another
warmer environment.
The charger’s vents are blocked, causing its
internal components to overheat.
Avoid blocking the vents.
The cooling fan is not running.
Contact a Hitachi Authorized Service Center
for repairs.
The USB power lamp
has switched o
ff
and the
USB device has stopped
charging.
The battery’s capacity has become low.
Replace the battery with one that has
capacity remaining.
Plug the charger’s power plug into an
electric socket.
USB power lamp does not
switch o
ff
even though the
USB device has
fi
nished
charging.
The USB power lamp lights up green to
indicate that USB charging is possible.
This is not a malfunction.
It is unclear what the
charging status of a USB
device is, or whether its
charging is complete.
The USB power lamp does not switch o
ff
even when charging is complete.
Examine the USB device that is charging to
con
fi
rm its charging status.
Charging of a USB device
pauses midway.
The charger was plugged into an electrical
socket while the USB device was being
charged using the battery as the power
source.
This is not a malfunction.
The charger pauses USB charging for about
5 seconds when it is di
ff
erentiating between
power sources.
A battery was inserted into the charger while
the USB device was being charged using a
power socket as the power source.
Charging of the USB device
pauses midway when the
battery and the USB device
are being charged at the
same time.
The battery has become fully charged.
This is not a malfunction.
The charger pauses USB charging for
about 5 seconds while it checks whether
the battery has successfully completed
charging.
Charging of the USB
device doesn’t start when
the battery and the USB
device are being charged
at the same time.
The remaining battery capacity is extremely
low.
This is not a malfunction.
When the battery capacity reaches a certain
level, USB charging automatically begins.
0000Book̲CH3656DA.indb 13