39
CP-X444(C11XMB)/CP-X440(C11XM25)
Power sheet
POWER UNIT(CIRCUIT)
Bracket
4. Putting the power supply unit together after the maintenance of the POWER UNIT (CIRCUIT) and/or the
POWER UNIT (BALLAST).
Warning
Attach Power Sheet so that its
shaded edge is inserted between
POWER UNIT(CIRCUIT) and the
bracket correctly.
5. Caution when connecting flexible flat cables of LCD panels.
A connector P601 on the PWB assembly MAIN is different from P501 and P701. Insert a cable correctly
and tighten firmly.
P601
P501,P701
Cable of LCD panel
Cable of LCD panel
WARNING
Assemble the power supply unit with care to achieve the required insulation. Incor-
rect assembly could cause a fi re and/or an electric shock.
Power PWB Holder