13 X 9 MODE (117 stopping positions)
Press the
“INPUT” button on the CLU-914MP
remote 5 times to activate the 117 stopping positions.
The raster will blink and the cursor will flash indicating 13 X 9 MODE.
NOTE:
This is the normal mode when entering the digital convergence adjustment mode.
Sometimes during adjustment, S-Distortion can occur. This is when the line has a noticeable wavy
appearance at a certain location. If this is encountered, enter the (5X7) mode and readjust the line. Then
perform Calculation. It may be necessary to return to the (3X3) mode as well.
Note: Store will also perform Calculation.