2-14
TEMP SENSOR DATA SETTING
2-14.1
Background and Outline
The TEMP Sensor is in the Drive PWB assembly in the OPT unit, and is monitoring inner temperature
.
LC67 Sensor: I608 (AD7414) on DRIVE P.W.B.
Main micro in Digital Core checks that temperature, and indicates LED alarm if the
temperature exceeds the limit.
i ) High Temperature: Alarm message is displayed for 5 minutes and
Power will be shut down with cool-down sequence.
(Only the power button is acceptable. Any menu and
message OSD cannot be displayed.)
ii ) IL01 failed or not connected: TEMP LED and LAMP LED are blinking
alternately. (Cycle; 1sec)
2-14.
2 Purpose
It's important to set the limiting data correctly. To do so, follow the next procedure.
2-14
.3 Adjustment Spec.
Adjustment procedure
1) Open ADJ menu and select DEVICE on the third page.
2) Input the data DEVICE "63" then press SELECT and input "ITEM" 0" then press SELECT to see
3) To change temperature limit, input the data DEVICE "13" then press SELECT, and input ITEM "0"
then press SELECT and input the adjustment data according to the below table.
4) Finally press SELECT to write.
BACK TO ADJUSTMENTS
4
8
Input Data
DATA(hex)
MODEL
No.72
(Default data)
(4B)
50VS69A
40
LC67
55VS69A
62VS69A
40
40
the current temperature data.
Summary of Contents for 50VS69A
Page 56: ...CONNECTION DIAGRAM TABLE OF CONTENTS 55 LC67 ...
Page 57: ...LC67 56 FINAL WIRING DIAGRAM TABLE OF CONTENTS ...
Page 58: ...LC67 57 FINAL WIRING DIAGRAM TABLE OF CONTENTS ...
Page 59: ...LC67 58 FINAL WIRING DIAGRAM TABLE OF CONTENTS ...
Page 60: ...LC67 59 FINAL WIRING DIAGRAM TABLE OF CONTENTS ...
Page 69: ...FINAL ASSEMBLY GUIDE TABLE OF CONTENTS 68 LC67 ...
Page 70: ...FINAL ASSEMBLY GUIDE 69 LC67 ...
Page 71: ...FINAL ASSEMBLY GUIDE 70 LC67 ...
Page 72: ...FINAL ASSEMBLY GUIDE 71 LC67 ...
Page 73: ...FINAL ASSEMBLY GUIDE 72 LC67 ...
Page 74: ...FINAL ASSEMBLY GUIDE 73 LC67 ...
Page 75: ...FINAL ASSEMBLY GUIDE 74 LC67 ...
Page 104: ...PRINTED CIRCUIT BOARDS LC67 POWER PWB Solder side LC67 103 ...
Page 122: ......