Data 

 

Values 

Supply voltage: 230 VAC  
Internal voltage: 36/24 VDC (+/- 5 %) 
Nominal current: 3A 
Max internal current: 10A 
Allowed temperature: 0 till +50 °C 
Max voltage/current for relays: 230 VAC / 10A 

 
Fuse 

6,3A slow, 5x20mm 

 
Inputs 

Open Signal 
Close signal 
 

Connections 

12 x screw terminals for motor/encoder/signals 
Supply cable: IEC C14  
 

Relay contacts 

Obstruction 
Closed door position 
Open door position 
 

Buttons 

Normal operation/learning trip 
2-Threads [COM to open or close] / 1-Thread [COM to open/close] 

 

Dimensions 

410x160x70mm 
 
 
 

 

Summary of Contents for Viksam 3.0

Page 1: ...Viksam 3 0...

Page 2: ...Voltage supply 5 3 2 Motor and encoder connection 5 3 3 Interface and settings 6 3 4 Pinch crushing protection 6 3 5 Relay contacts 7 3 6 Blocking 7 3 7 Door hanging 7 4 Commissioning 8 4 1 Learning...

Page 3: ...rature 0 till 50 C Max voltage current for relays 230 VAC 10A Fuse 6 3A slow 5x20mm Inputs Open Signal Close signal Connections 12 x screw terminals for motor encoder signals Supply cable IEC C14 Rela...

Page 4: ...ackside of the hanger rail Each angle needs 4x square nuts and 4x hexagonal screws Adjust the angles to approx 10mm from each pilaster Mount the idler pulley furthest into the track of the bracket to...

Page 5: ...lley is pressed against the frame See the figure below This requires that the angle is correctly mounted on the rail and that the idler pulley has some space left in the track Belt tension adjustment...

Page 6: ...ied with a quick connect IEC C14 cable for the power supply This is connected to 230 VAC and earth A fuse 2 5A slow is located in the connection housing 3 2 Motor and encoder connection The motor is d...

Page 7: ...n 9 and 12 If there is no signal or if both signals are active the door will stay in its current position If the door control is connected to a common opening and closing signal 1 wire communication t...

Page 8: ...e opening closing phase the door will always reverse but the signal can be taken from the relay contacts on the inside of the control After 3 attempts the control will wait for a new signal 3 7 Door h...

Page 9: ...ay in the closed position NOTE If it stays in the open position the encoder may be incorrectly connected see section 3 2 When the learning journey is finished the push button must be set to the normal...

Page 10: ...www hissmekano se Manual Viksam 3 0 version 2 October 2022 9 5 Troubleshooting...

Page 11: ...9 Motor 3710331 Motor tension roller angle 3710298 Power supply unit 3710332 7 Maintainance 7 1 Lubrication of tension roller Push the roller down so that a small gap appears and spray some spray grea...

Reviews: