Hispacold Ecomaster Clima MH-012 User Manual Download Page 2

Manual 

 
 
 
 
 
 

 

 

 
 
 
 
 

 

MH-012  Ecomaster Clima user manual  

 

2/7 

 

 

 

 

 

 
 
 

Document privacy 

PU 

Public 

RE 

Restricted 

 

CO 

Confidential 

 

Redacted by

:  Pablo Garcia Piosa 

Date: 

10-10-18 

Category: 

Manual 

Revision control 

Version 

Date 

Change 

Comments 

V1 

09-23-05 

Juan Bernal 

The new features corresponding to software version 1.0 
are added to the manual 

 

From this version on it will be possible to control a 
motorized valve for the roof and floor heating 

circuit. 

 

It now includes the possibility of programming the 

strictness of the filter applied to the reading from 
the temperature sensors. 

V2 

10-21-05 

Juan Bernal 

Comments added 

V3 

10-10-18 

Pablo García 

New format 

Summary of Contents for Ecomaster Clima MH-012

Page 1: ...Ecomaster Clima user manual Reference MH 012 ...

Page 2: ...V1 09 23 05 Juan Bernal The new features corresponding to software version 1 0 are added to the manual From this version on it will be possible to control a motorized valve for the roof and floor heating circuit It now includes the possibility of programming the strictness of the filter applied to the reading from the temperature sensors V2 10 21 05 Juan Bernal Comments added V3 10 10 18 Pablo Gar...

Page 3: ...al description 4 Temprature set 4 1 1 Varying the speed of the Evaporator Ventilators 4 1 2 Changing the flap position 5 1 3 Activation of ECO 5 1 4 Activation of De humidification Reheat 5 1 5 Check Temperatures 5 1 6 Variation of Contrast and Brightness 6 1 7 2 Autochecking error codes 7 ...

Page 4: ...orced chill mode LO and acti vates its maximum cooling power the screen displays LO When the temperature is set above 27ºC 82ºF the system engages forced heat mode HI and activates its maximum heating power the screen displays HI Varying the speed of the Evaporator Ventilators 1 2 The speed of the evaporators can be varied from levels 1 to 3 When the speed is altered the system goes into manual mo...

Page 5: ...s operating in air conditioning mode and the interior temperature is 2ºC higher than that selected Set the flaps will switch to Automatic mode and will close Activation of ECO 1 4 If the 4 key is pressed the letters ECO will appear on screen and the compressor will be disconnect ed The system switches into Semi automatic mode Pressing the 4 key will have no effect if the system is not working in D...

Page 6: ...e the air conditioning unit is switched on For this purpose it is necessary to use the following key combination in which the first key pressed must be held down while the second key is pressed several times in succession to raise or lower the parameter in question 2 8 Greater brightness 2 7 Less brightness 3 8 Greater contrast 3 7 Less contrast 2 3 Factory settings for brightness and contrast ...

Page 7: ...LB Left Adjustable Evaporator Ventilator Outlet Shorted CNDB Adjustable Condenser Ventilator Outlet Shorted EVAP1 Evaporator Ventilator Outlet Shorted Speed 1 EVAP2 Evaporator Ventilator Outlet Shorted Speed 2 EVAP3 Evaporator Ventilator Outlet Shorted Speed 3 CND Condenser Blower Outlet Shorted C1 Underfloor Heater Outlet Shorted Speed 1 C2 Underfloor Heater Outlet Shorted Speed 2 POT Error in th...

Reviews: