background image

 

7

 

HSK2411202016 | Dynamic Terminal Ku 8X8 V2 | Quick Start Installation Guide 

 

 

 

Troubleshooting 

Issue 

Workaround 

WI-FI connection cannot be established between 
the smartphone and the terminal.

 

Make sure a WI-FI connection is available on the 
smartphone. Check for relevant integration 
instructions 

Terminal cannot establish satellite connectivity 
(Slow Flashing Green). 

Check the service plan status in the hiSky mobile 
app. 

Unsuccessful registration to hiSky mobile app. 

Internet connection is required for the initial Login. 

L

ED is 

Flashing red 

No service due to registration problem- Ensure 
initial registration to hiSky network and plan 
activation. 

 

IoT Dynamic Ku 8X8 V2 Terminal Specifications 

 

 

 

 

 

 

Value 

                          Parameter  

21dBi 

Antenna Gain Rx & Tx@90°> 

18dBi 

Antenna Gain Rx & Tx@30°> 

2.5dB 

Noise figure  

H / W / D:  291 / 187 / 42 mm 

Mechanical Dimensions 

2.3Kg 

Weight 

12-24 VDC

 

Voltage range: 

10mW 

Sleep power consumption 

10W 

Idle power consumption 

24W 

Receive only power consumption 

48W 

Max power consumption 

-20°C to 60°C / / -4°F to +131°F 

Operational Temperature 

IP67 

Dust and water ingress 

Circular connector 19 pin 
DC, Ethernet, serial- 233,422, Wake up I/O 

Interfaces 

13.75 GHz - 14.50 GHz 

Transmit Antenna Frequency Range 

10.7 GHz - 12.75 GHz 

Receive Antenna Frequency Range  

1560MHz - 1610MHz 

GPS Frequency Range  

2412MHz - 2462MHz 

WLAN 2.4GHz Frequency Range  

2402MHz - 2480MHz  

Bluetooth Frequency Range  

6Kbps to 120Mbps 

MODEM Data Rate 

Summary of Contents for Dynamic Terminal Ku 8X8 V2

Page 1: ...ation Guide Document P N QSIG0003 Document Version V 3 Creation Data February 2022 Last update April 1st 2022 Proprietary Notice This document is the proprietary property of hiSky Ltd Copying or other...

Page 2: ...transmission such as fleet management data environment conditions alarm events sensors loggers operations and much more as well as command and control of sensors and remote systems Related Documents F...

Page 3: ...WARNING Both the power supply and the inverter must be certified for safety electromagnetic compatibility and all the regulations in the region where the terminal will operate Follow all safety instr...

Page 4: ...Software Update b Click Ok to continue with the software update process c Click on MANAGE UPDATES d Click on CHECK FOR UPDATES FROM NMS e Select the latest Ku software version for your terminal f Down...

Page 5: ...te Parameters section ensure that the correct beam number is being used If not select the relevant beam number f Click SAVE g Restart the terminal by pushing the power button Ensure that the terminal...

Page 6: ...ution must meet the local standard requirements The installer is responsible to make sure the installation will meet usage guidelines WARNING Radio frequency hazard keep a distance of at least 25 cm d...

Page 7: ...stration to hiSky network and plan activation IoT Dynamic Ku 8X8 V2 Terminal Specifications Value Parameter 21dBi Antenna Gain Rx Tx 90 18dBi Antenna Gain Rx Tx 30 2 5dB Noise figure H W D 291 187 42...

Page 8: ...ccorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti Advarsel Dette varselsymbolet betyr fare Du befinner deg i en s...

Page 9: ...abelle mechanischen und umweltbezogenen Spezifikationen definiert Um Luftstrom Einschr nkungen zu verhindern k nnen Sie mindestens 6 Zoll 15 2 cm von Freiraum um die L ftungs ffnungen Avvertenza Per e...

Page 10: ...es ao circuito de fornecimento de energia para n o sobrecarregar a instala o Atenci n Poner mucho cuidado al conectar los equipos al circuito de alimentaci n a fin de no sobrecargar el cableado Varnin...

Page 11: ...Details can be found on the hiSky Web site located at https www hiskysat com Product Documentation Compliance with WEEE Directive When hiSky products have reached the end of their useful life hiSky d...