background image

Problem 

Cause 

Refrigerator can’t 

start 

1.1 Is the power cord connecting well

 

1.2 Is the power voltage too low

 

1.3 Is the ambient temperature too low?     

1.4 Is the circuit on power?     

1.5 Is there some default in compressor 

1.6  Is the refrigeration system blocked by ice or dirty,  please stop the unit and 

restart after 10 minutes to see if the compressor can start. 

Weak cooling effects 

2.1 Is there any heat source around the refrigerator?   

2.2 Is there enough space around the refrigerator for rejection of heat?   

2.3 Is the setting of the temperature appropriate?   

2.4 Is there too much food or overheating food in it? 

2.5 Does the door open frequently?   

2.6 Is the door completely closed?     

2.7 Does the gasket destroyed or distort?   

2.8 Does the gas leak? 

The unit can not stop 

running 

3.1 Is there any heat source around the refrigerator?   

3.2 Is there enough space around the refrigerator for rejection of heat? 

3.3 Is the setting of the temperature appropriate?   

3.4 Is there too much food or overheating food in it? 

3.5 Does the door open frequently? 

3.6 Is the door completely closed? 

3.7 Does the gasket destroyed or distort?   

3.8 Is the thermostat good operation? 

3.9 Does the gas leak? 

Ice up in the freezing 

chamber 

4.1 Is the setting of the temperature appropriate? 

4.2 Is there multi-moisture food and too close to the back wall of the refrigerator?   

4.3 Is the ambient temperature too low?   

4.4 Is the electric parts on good condition, specially the thermostat wich will 

cause the unit non-stopping 

Abnormal noise 

5.1 Is the refrigerator stably placed? 

5.2 Does the refrigerator bump other objects? 

5.3 Whether the internal accessory of the refrigerator is in the right place. 

5.4 Whether the water plate of compressor is fall from the unit. 

5.5 Does the tube of the refrigeration system bump each other? 

5.6 The noise sound likes Water flow inside the refrigerator, in fact,it is normal, 

which is caused both when refrigerator start and shut-down; in addition, 

frost-dissolving  causes this sound, too, which is a normal phenomenon. 

5.7 There will be a cracking sound in the cabinet  ,when the cabinet or cabinet 

accessory contracting or expanding, this sound will be made, which is normal. 

5.8 The motor operation sound in the compressor is appears to be louder at night 

or begin starting. which is a normal phenomenon; also the uneven placing would 

lead to too much running noise.   

There is a peculiar 

smell in the units 

6.1 Is the food with special smell sealed tight? 

6.2 Does it have long time storing food or degenerated food?   

6.3 Whether the internal cabinet needs cleaning. 

the forefront or the 

middle cabinet heats 

7.1 As fridge Anti-condensation tube is placed here and caused the above 

phenomenon, which is normal. 

Summary of Contents for RS-09DC4S Series

Page 1: ...REFRIGERATOR Service manual MODEL RS 09DC4S BD 65 NOTE This is a basic model the shape and specification of refrigerator is subject to change ...

Page 2: ...PARTS INENTIFICATION NOTE This figure is only a sketch Of the Refrigerator and the actual Products may differ from it CIRCUIT DIAGRAM COOLING DIAGRAM ...

Page 3: ...e guide for Disassembly Common parts of Refrigerator The instruction of replacing thermostat The location of the thermostat remove screws of top cover Capillary Compressor Dry filter Condenser Evaporator ...

Page 4: ...ire Take out the thermostat The instruction of replacing PTC Starting relay and Overload protector Take down Spring tap and Cover Unplug the connecting wire Take out the PTC Starting relay and Overload protector Door Reversal ...

Page 5: ...TROUBLESHOOTING The common problem judging method ...

Page 6: ...opriate 4 2 Is there multi moisture food and too close to the back wall of the refrigerator 4 3 Is the ambient temperature too low 4 4 Is the electric parts on good condition specially the thermostat wich will cause the unit non stopping Abnormal noise 5 1 Is the refrigerator stably placed 5 2 Does the refrigerator bump other objects 5 3 Whether the internal accessory of the refrigerator is in the...

Page 7: ...nit will work not well Phenomenon of failure a higher pressure of liquid cycle system than norm b higher temperature of condenser c larger electric current of compressor d there maybe ice on the suction tube e when gas is too much some gas liquid might goes back into compressor compressor will be damaged by liquid First stop unit for several minutes and then open charging tube discharge all of gas...

Page 8: ...int is there 2 There is some thing that blocked the liquid cycle system A Ice blocking Sometime because unknown reason water comes into liquid cycle system the capillary will be blocked by water after unit runs for period of time Phenomenon of failure The unit works well in the inception after period of time the ice appears in the capillary and becomes more and more till blocks the hole of capilla...

Page 9: ... Please put the food properly 5 Wind door is broken Replace wind door 6 Fan motor is broken Replace fan motor Note Before doing these operations above disconnect the main power supply Failure to do so could result in electrical shock or personal injury In case of any detailed technical information please check with the technical specifications announcements of Maintenance operation safety In order...

Page 10: ...oper maintenance tools Improper use tools may cause bad contact or fastening rickety and accidents 6 Wire connection Reconnecting first must weld or use connected terminals and insulation tape sealing ensure good contacts 7 Insulation testing after the maintenance assembly the insulation resistance testing must use a multimeter to confirm insulation resistance up to 1 M Ω above can electrify opera...