2
5cm min.
5cm
min.
WARNING
Indoor unit
Drain hose
Outside drainage
Fig.1
Fig.2 (Front View)
A V O I D:
·direct sunlight.
·nearby heat sources that may affect performance of
the unit.
·areas where leakage of flammable gas may be
expected.
·places where large amounts of oil mist exist.
DO:
·select an appropriate position from which every corner
of the room can be uniformly air-conditioned.(High on
a wall is best.)
·select a location that will hold the weight of the unit.
·select a location where tubing and drain hose have the
shortest run to the outside.(Fig.1)
·allow room for operation and maintenance as well as
unrestricted air flow around the unit.(Fig.2)
To prevent abnormal heat
g e n e r a t i o n
a n d
t h e
possibility of fire,do not
place obstacles, enclosures,
and grilles in front of or
s u r r o u n d i n g
t h e
a i r
conditioner in a way that
may block air flow.
1. GENERAL
This booklet briefly outlines where and how to
install the air conditioning system. Please read
over the entire set of instructions for the indoor
and outdoor units and make sure all accessory
parts listed are with the system before beginning.
1-1.Tools Required for Installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
,
5. Carpenter s level
6. Hammer
7. Drill
8. Tube cutter
9. Tube flaring tool
10.Torque wrench
11.Adjustable wrench
1-2.Optional Copper Tubing Kit
Copper tubing for connecting the outdoor unit to
t
h
e
indoor unit is available in kits which contain the
n
a
r
r
o
w
and wide tubing, fittings and insulation. Consult
1-3.Additional Materials Required for Installation
1. Refrigeration (armored) tape
2. Insulated staples or clamps for connecting wire
(See local codes)
3. Putty
4. Refrigeration lubricant
5. Clamps or saddles to secure refrigerant tubing
2. INSTALLATION SITE SELECTION
2-1.Indoor Unit
5cm
min.