SAFETY SUMMARY
WARNING
● Do
not
use
any
sprays
such
as
insecticide,
lacquer,
hair
spray
or
other
flammabl
e
gases
within
approximately
1.3m
(4
ft)
from
the
system.
● If
the
circuit
breaker
or
fuse
is
often
activated,
stop
the
system
and
contact
your
service
contractor.
● Check
that
the
ground
wiring
is
securely
connected.
If
the
unit
is
not
correctly
grounded,
it
may
cause
electric
shock.
Do
not
connect
the
ground
wiring
to
gas
piping,
condensate
piping,
lighting
conductor
or
ground
wiring
for
telephones.
● Before
performing
any
brazing
work,
check
to
ensure
that
there
is
no
flammabl
e
material
around.
When
using
refrigerant,
be
sure
to
wear
leather
gloves
to
prevent
injury
from
cold.
● Insulate
electrical
wiring,
condensate
piping,
and
electrical
components
from
threats
posed
by
burrowing
animals
and
temperature
extremes.
Failure
to
do
so
can,
over
time,
deteriorate
system
performance.
● Secure
the
cables.
External
forces
on
the
terminals
could
lead
to
a
fire
.
● Tighten
the
flar
e
nut
with
a
torque
wrench
in
the
specifi
d
manner.
Do
not
apply
excessive
force
to
the
flar
e
nut
when
tightening.
If
you
do,
the
flar
e
nut
can
crack
and
refrigerant
leakage
may
occur.
● When
maintaining,
relocating
or
disposing
of
the
unit,
dismantle
the
refrigerant
piping
after
the
compressor
stops.
● Highly
dangerous
electrical
voltages
are
used
in
this
system.
Carefully
refer
to
the
wiring
diagram
and
these
instructions
when
wiring.
Improper
connections
and
inadequate
grounding
can
cause
serious
injury
or
death.
● Perform
all
electrical
work
in
strict
accordance
with
this
installation
and
maintenance
manual
and
all
relevant
regulatory
standards.
● Use
specifi
e
d
cables
between
units.
● Be
sure
to
install
circuit
breakers
(ground
fault
interrupter,
isolating
switch,
molded
case
circuit
breaker
and
so
on),
with
the
specifie
d
capacity.
Ensure
that
the
wiring
terminals
are
tightened
securely
to
recommended
torque
specifications
If
a
circuit
breaker
or
fuse
is
frequently
activated,
shut
down
the
system
and
contact
your
service
contractor.
● Clamp
electrical
wires
securely
with
a
cable
clamp
after
all
wiring
is
connected
to
the
terminal
block.
In
addition,
run
wires
securely
through
the
wiring
access
channel.
● When
installing
the
power
lines,
do
not
apply
tension
to
the
cables.
Secure
the
suspended
cables
at
regular
intervals,
but
not
too
tightly.
● After
stopping
operation,
be
sure
to
wait
at
least
fiv
e
minutes
before
turning
off
the
main
power
switch.
Otherwise,
water
leakage
or
electrical
breakdown
may
result.
Disconnect
the
power
supply
completely
before
attempting
any
maintenance
for
electrical
parts.
Check
to
ensure
that
no
residual
voltage
is
present
after
disconnecting
the
power
supply.
● Insulate
the
refrigerant
pipe
connection
to
prevent
condensation.
● Be
sure
to
attach
the
cover
so
that
it
fit
s
securely
on
the
electrical
box
without
any
gaps.
Secure
the
cover
with
screws.
iv