Search and install "Hi-Mit
II
"
App from Google Play Store or iOS App Store.
Requirement to operation system of smart phone: Android
6
.0, iOS 1
0
.0 or a
later
version is recommended. Please scan the QR code on the right to
do
w
nload user manual
.
4.3
APP download
DSW
1
0xA0
0xA1
0xA2
0xA3
0xA4
0xA6
0xA7
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
0xA5
1 2 3 4
ON
OFF
Note: indicates the location of
DIP
switch. indicates no attention needed.
4.2
Electric meter
s
etting
4.1
DIP switch
s
etting
When multiple adapters (max.3) are connected to one H-NET communication cable, DSW1 has to be set.
When connected into Schneider electric meter, the slave address of the electric meter has to be
set. Communication parameter adopts default parameter of the electric meter. Baud rate: 19200,
parity: even. Slave address = corresponding refrigerant system 1, setting diagram is as
shown below:
4. Configuration
Ref. system No.: 0
Ref. system No.: n
Slave add.
:
n+1
A/C
A/C
Adapter
Router
Electric meter
Electric meter
Commu. cable
Slave add.: 1
A/C power line
A/C power line
5. Troubleshooting
Cause
Check if power line is connected, and if power supply is switched on.
Check if
network
of router is normal, and if
network
cable is disconnected.
Adapter has not yet finish the searching.
Check if communication distance of H-NET is out of specified range, and
if
WiFi
signal is normal.
Check if 485 communication is out of specified range or disconnected
,
and
if the address setting is proper.
6
Failure
WLAN status LED OFF
System status LED ON
A/C off-line or out of control
Electric meter off-line
Power status LED OFF