Hisense HCCS-H64H2C1M Installation & User Manual Download Page 7

The device is provided along with four AC plugs complying with British standard, European standard, 

American standard, Australian standard, as well as two bolts and two expansion plugs.

 3.2 On-site 

p

reparations

Following items should be ready before installation. 

necessary, for commu

n

ication with A/C, 

commu. distance < 1000m
not necessary, for commu

n

ication with electric meter,   

commu. distance < 600m

3

. Installation

3.1

 

Components 

l

ist

When unpacking, please check if all the following items are complete and intact. 

3.3

 

On-site 

c

onfirmation

Select a place with the consent of customer and also suitable for the adapter installation.

 

DC12V power line

H-NET commu. cable

485 commu. cable

Wireless router

Internet cable

preferred: TP-Link, Netgear 

100Base-TX

necessary, make sure have access to internet. When 

adapter connects 

to

 router in a wireless manner, 

straight line distance < 15m, and supports only 2.4GHz

not necessary, applicable only when connecting to internet 

with cable, commu. distance < 50m

Check the installation location and power

supply

.

Check if all the embedded lines are ready

.

Check if the air conditioner can run properly

.

Check if WiFi 

covers

 when wireless connection is

ad

o

pted.

not necessary, applicable only when using DC12V 

backup power interface

When power ad

a

pter is adopted, please confirm the

type of plug on-site, and select a proper AC plug.

Check if air conditioner is powered off

.

3.4 Installation 

p

rocedure

1) Drill as per the figure in the selected wall

(diameter: 6mm, pitch of holes: 44mm).
2) Position the expansion plugs into the holes

and insert the bolts with 

3

~

5

mm protruding

from the expansion plug.

3) Screw out the fixing bolts from the base of

adapter, and remove the bottom cover, then

perform wiring according to diagram.

Item

Wall

Pitch of holes

44mm

Bolt protruding 

from the wall  

3

mm

1

1

1

1

preferred: 0.75mm

2

 above, shielded twisted pair  

Specification

preferred: 0.75mm

2

 above, shielded twisted pair

Item 

         Adapter        

Installation Manual 

   Power Adapter

Accessory Pouch

Figure

Quantity

preferred: 0.75mm

2

 above, shielded twisted pair  

Requirements

NOTE

4

Summary of Contents for HCCS-H64H2C1M

Page 1: ...Hi Mit Adapter Model HCCS H64H2C1M EN INSTALLATION USER MANUAL...

Page 2: ......

Page 3: ...2 1 Main features 2 2 Description of parts 2 3 General data 3 1 Components list 3 2 On site preparations 3 3 On site confirmation 3 4 Installation procedure 3 5 Electrical wiring CONTENTS 1 2 3 3 4 4...

Page 4: ...of electric shock The adapter is non washable Otherwise it may lead to electric shock or a fire The power line and signal wire have to be kept away from wireless transmitter Please read this chapter t...

Page 5: ...s both wired and wireless routers Only one type should be selected for use 4 Remote control air conditioner on ON OFF Temperature Mode Fan Louver settings etc 5 Remote control water module on ON OFF T...

Page 6: ...nds Meanwhile the system status LED flashes The whole system is restored to factory settings connect to power adapter in accessories connect to commu bus of outdoor indoor unit Top cover Bottom cover...

Page 7: ...connecting to internet with cable commu distance 50m Check the installation location and power supply Check if all the embedded lines are ready Check if the air conditioner can run properly Check if W...

Page 8: ...able connects to the RS485 end of electric meter A connects to D1 and B connects to D0 Internet cable connects to LAN port of router when adopted wired connection Power adapter connects to the plug of...

Page 9: ...meter has to be set Communication parameter adopts default parameter of the electric meter Baud rate 19200 parity even Slave address corresponding refrigerant system number 1 setting diagram is as sho...

Page 10: ...e Text der EU Konformit tserkl rung ist unter der folgenden Internetadresse verf gbar http www hisense vrf com Qingdao Hisense Hitachi Air conditioning Systems Co Ltd No 218 Qianwangang Road Economic...

Page 11: ...is connected Consult the dealer or an experienced radio TV technician for help To satisfy RF exposure requirements a separation distance of 20 cm or more should be maintained between the antenna of t...

Page 12: ...ianwangang Road Economic and Technological Development Zone Qingdao China http www hisense vrf com E mail export hisensehitachi com The Company is committed to continuous product improvement We reserv...

Reviews: