46
6.5 Damper
Rated voltage:DC12V
Rated current:60mA
6.5.1 Basic parameters
6.5.2 Checking method
6.Circuit and checking
1.Check the connecting wiring of the damper is well or not,repair if it is
broken.The damper corresponding pin No.1~6 on CN6 connector of
mainboard,as the drawing below.
2.The damper will turn on and off for one time after power-on,if not,
change the mainboard first and change the damper if problem
remains.