Specifications
26
ML19G User Manual, January 2015
Environmental
Operating Temperature
0° to 50°C (32° to 122°F)
Storage Temperature
-20° to 60°C (-4° to 140°F)
Humidity
20% to 90% non-condensing
Operating Shock
15 g, 6 msec, half-sine
Operating Vibration (sine)
1�0g, swept sine 9 – 500 Hz
Transport Vibration
(random)
0�1g
2
/ Hz, 10 – 200 Hz
0�03g
2
/ Hz, 200 – 2000 Hz
Altitude
• Operating: up to 10,000 feet
• Non-operating: up to 40,000 feet
Compliances and Certifications
Electrical
• UL 60950 3
rd
Edition / cUL Recognized Component (File No�
E212889)
• UL 508A Listed (File No� E318630)
• FCC Class A
• CAN ICES-3A/NMB-3A
• CE
Environmental
• IEC 60721-3 (Reliability)
• WEEE (Registration No� WEE/DJ1859ZX for UK only)
Enclosure
UL 50E (File No� E318630)
Hazardous Location
• For monitors with model numbers HIS-ML19- _ _ HG only:
UL Rated for Hazardous Locations: Industrial Control
Equipment for Hazardous Location: Listed for Class I,
Division 2 for Groups A, B, C, and D; Recognized for Class
II, Division 2 for Groups F and G; Class III; Temp Code T5
(File No� E328481) per ANSI/ISA 12�12�01-2007
• For monitors with model numbers HIS-ML19- _ _ UG only:
UL Rated for Hazardous Locations: Industrial Control
Equipment for Hazardous Location: Listed for Class I,
Division 2 for Groups A, B, C, and D; Recognized for Class
II, Division 2 for Groups F and G; Class III; Temp Code T4A
(File No� E328481) per ANSI/ISA 12�12�01-2007