32
Installation RSPE 30/32/35/37
Release 12 10/2015
1.7
Management interfaces
1.7.1
V.24 interface (external management)
A serial interface is provided on the RJ11 socket (V.24 interface) for the local
connection of an external management station (VT100 terminal or PC with
corresponding terminal emulation). This enables you to set up a connection
to the Command Line Interface CLI and to the System Monitor.
The socket housing is electrically connected to the front panel of the device.
The V.24 interface is electrically insulated from the supply voltage.
Figure 1: Pin assignment of the V.24 interface and the DE9 connector
Note:
The terminal cable is available as an accessory.
1.7.2
SD card interface
The SD card interface allows you to connect the AutoConfiguration Adapter
ACA31 storage medium. This is used for saving/loading the configuration
data and diagnostic information, and for loading the software.
See “Accessories” on page 63.
For information about the position on the device see
“Rear view” on page 21
.
On the front of the device there is an LED display that informs you about the
status of the interface.
Only use Hirschmann SD cards.
VT 100 terminal settings
Speed
9600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DE9
RJ11
DE9
Summary of Contents for RSPE 30