Hirschmann RS2-4R Description And Operating Instructions Download Page 5

5

– Pin configuration

of the RJ45 socket,

RS2-4R:

– 1 line pair: pin 3 and pin 6
– 1 line pair: pin 1 and pin 2
– remaining pins: not used.

Fig. 3: Pin configuration of an TP/TX 
interface

100 Mbit/s connection

100 MBit/s F/O ports (DSC sockets) allow
terminal equipment or independent
network segments complying with the
standard IEEE 802.3 100BASE-FX to be
connected.
State on delivery: full duplex.

Note:

Make sure, that you conncet LH ports

only to LH ports, SM ports only to SM ports
and MM ports only to MM ports.

V.24 interface (external management)

A serial interface for local connection of
– an external management station (VT100

terminal or a PC with corresponding ter-
minal emulation) is available via the RJ11
socket (V.24 interface). A link can thus be
established with the User Interface UI.

– an AutoConfiguration Adapter ACA 11 is

available via the RJ11 socket (V.24 interfa-
ce).

VT100 terminal settings:
– Speed:

9,600 Baud

– Data:

8 bit

– Stopbit:

1 bit

– Handshake: off
– Parity:

none

The V.24 interface baud rate can be configu-
red to 9,600 or 19,200 baud. The factory
default is 9,600 baud.

The socket casing is galvanically connected
to the front panel of the device. 

Note:

In chapter 6 „Technical data“ you

find the order number for the terminal
access cable which is to be ordered
separately.

Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1

– blinking green (3 blinks per period)

– port is disabled

– running light:  – initialization phase after a

reset

DA 1 bis 4 – Data 

(yellow LED)

– not lit:

– no data traffic

– flashes yellow:– data traffic
– running light:  – initialization phase after a

reset

1.8 CONTROLS
2-pin DIP switch

Using the 2-pin DIP switch on the RS2-4R
front panel
– on RS2-4R the HIPER-Ring function can be

enabled or disabled with the switch 

RING

.

State of delivery: position 0 (Off), i.e. nor-
mal function.

– with the 

RM 

switch the RM functionality

(Redundancy Manager) can be switched
on or off when HIPER-Ring function is
activated. State of delivery: switch in posi-
tion 0 (Off), i.e. RM function not active.

Fig. 2: 2-pin DIP switch on RS2-4R

RING RM port 3 + 4

Redundancy

Manager

0

-

TP port: Autonegotiation

off

FX port: 100 Mbit/s fullduplex

1

0

Ring port: 100 Mbit/s fulldupl

off

1

1

Ring port: 100 Mbit/s fulldupl.

on

Tab. 1: DIP switch function

1.9 INTERFACES
10/100 MBit/s connection 
(Twisted Pair)

10/100 Mbit Ports (8-pin R45 sockets) allow
terminal equipment or independent net-
work segments complying with the stan-
dards IEEE 802.3 100BASE-TX / 10BASE-T
to be connected. These ports support auto-
negotiation, autocrossing and the auto-
polarity function. 

Factory settings: autonegotiation active (not
valid for HIPER-Ring ports).

The socket casings are electrically connec-
ted to the front panel of the RS2-4R.The pin
configuration complies with MDI-X.

0

1

RING

RM

HIPER-Ring 

Redundancy manager

Fig. 4: Pin configuration of the V.24 
interface

– AutoConfiguration Adapter ACA:

The ACA is a device for saving the confi-
guration data of a MICE, RS2-4R, RS2-
16M, RS2../.. oder MACH 3000 switch. If
one switch should fail, the ACA facilitates
a conceivable simple assumption of the
configuration data by an alternative
switch of the same type. 
In case of a reset the switch compares the
contents of the ACA with its own configu-
ration data. If the configuration data do
not correspond, the switch takes over the
configuration data of the ACA.

6pin terminal block

The supply voltage and the indicator
contact are connected via a 6pin terminal
block with screw rast mechanism.

z

Warning!

The RS2-4R equipments are desi-
gned for operation with a safety
extra-low voltage.Thus, they may
only be connected to the supply vol-
tage connections and to the signal
contact with PELV circuits or
alternatively SELV circuits with the
voltage restrictions in accordance
with IEC/EN 60950.

– Voltage supply

: Redundant voltage sup-

plies are supported. Both inputs are
decoupled. There is no load distribution.
With redundant supply, the power pack
supplies the RS2-4R only with the higher
output voltage. The supply voltage is elec-
trically isolated from the housing.

– Indicator contact: 

The indicator contact is used to supervise
the functions of the RS2-4R and thus faci-
litates remote diagnosis.
Contact interrupt indicates the following
by means of a potential-free indicator
contact (relay contact, closed circuit):

Pin 1

Pin 1

Pin 8

Pin 5

Pin 6

RJ11

DB9

2
3

5

1
2
3
4
5
6

CTS
n.c.
TX
GND
RX
RTS

RS1

Line structure

RS2-16M

RS2-16M

RS2-../..

MICE

RS2-4R

Fig. 5: Line structure

Summary of Contents for RS2-4R

Page 1: ...nectors and up to two fiber optic ports 100 Mbit s ports The fiber optic ports to connect further more switches are available with FX interfa ces depending on the RS2 4R model with multimode singlemod...

Page 2: ...with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and corr...

Page 3: ...applied to the device as described in the operating instructions z Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel th...

Page 4: ...S2 4R runs a hard ware self test During operation an integra ted watch dog monitoring unit monitors the function of the software Reset The RS2 4R will be reset by the following actions management inpu...

Page 5: ...lduplex 1 0 Ring port 100 Mbit s fulldupl off 1 1 Ring port 100 Mbit s fulldupl on Tab 1 DIP switch function 1 9 INTERFACES 10 100 MBit s connection Twisted Pair 10 100 Mbit Ports 8 pin R45 sockets al...

Page 6: ...00 you can close the two ends of a line structured backbone to form a redundant ring The RS2 4R is integrated into the ring via the HIPER Ring ports ports 3 and 4 Within a redundant ring any mixture o...

Page 7: ...m version 5 5 on Note The Web based interface uses the plugin Java runtime environment version 1 3 If this is not installed on your compu ter an installation via the internet is started automatically...

Page 8: ...4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6...

Page 9: ...supply voltage 2 present 1 x red LED FAULT indicator contact is open and indicates error 1 x green yellow LED RM redundancy manager autoconfig adapter Port status 4 x green LED LS 1 to 4 link state 4...

Page 10: ...nd Network Solutions Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 49 7127 14 1551 E Mail ans support hirschmann de Internet http www hirschmann com Printed in Germ...

Reviews: