Hirschmann RS2-4R Description And Operating Instructions Download Page 3

3

Based specifications and 
standards:

The devices fulfil the following
specifications and standards: 
– EN 61000-6-2:2001 Generic standards –

Immunity for industrial environments

– EN 55022:1998 + A1 2000 – Information

technology equipment – Radio disturban-
ce characteristics

– EN 60950:1997 – Safety of Information

Technology Equipment (ITE)

– EN 61131-2:1994 + A12 2000 –

Programmable Controllers

– FCC 47 CFR Part 15:2000 – Code of Federal

Regulations

– Germanischer Lloyd, Rules for

Classification and Construction VI - 7 - 3
Part 1, Ed. 2001.

– cUL 508:1998 – Underwriters Labratories

Inc. Safety for Industrial Control
Equipment.

– cUL 1604 Electrical Equipment for Use in

Class I and Class II, Div. 2 and Class III
Hazardous (Classified).

– cUL 60950 Safety for Information

Technology Equipment.

Certified devices are marked with a
certification identifier.

7

Notes on CE 
identification

The devices comply with the regula-
tions of the following European
directive:

89/336/EEC
Council Directive on the harmoniza-
tion of the legal regulations of mem-
ber states on electromagnetic com-
patibility (amended by Directives
91/263/EEC, 92/31/EEC and
93/68/EEC).

The EU declaration of conformity is
kept available for the responsible
authorities in accordance with the
above-mentioned EU directives at:

Hirschmann Electronics 
GmbH & Co. KG
Automation and Network Solutions
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Tel+49 (0)7127 14-1480

The product can be used in the resi-
dential sphere (residential sphere,
business and trade sphere and small
companies) and in the industrial
sphere.
– Interference immunity: 

EN 61000-6-2:2001

– Radio interference level: 

EN 55022:1998 + A1 2000 Class A

– trained or directed or authorized to

switch on and off, to ground and to label
power circuits and devices or systems in
accordance with current safety enginee-
ring standards

– trained or directed in the care and use of

appropriate safety equipment in accor-
dance with the current standards of safety
engineering

– trained in providing first aid.

General Safety Instructions

This device is electrically operated.

Adhere strictly to the safety requirements
relating to voltages applied to the device as
described in the operating instructions!

z

Warning!

Failure to observe the information
given in the warnings could result in
serious injury and/or major damage.

Only personnel that have received
appropriate training should operate
this device or work in its immediate
vicinity. The personnel must be fully
familiar with all of the warnings and
maintenance measures in these
operating instructions.

Correct transport, storage, and
assembly as well as careful operati-
on and maintenance are essential in
ensuring safe and reliable operation
of this device.

Use only undamaged parts!

These products are only to be used in

the manner indicated in this version of the
”Description and Operating Instructions”.

Particular attention is to be paid to all

warnings and items of information relating
to safety.

z

Warning!

Any work that may have to be per-
formed on the electrical installation
should be performed by fully
qualified technicians only.

z

Warning!

LED- or LASER components accor-
ding to IEC 60825-1 (2001): 
CLASS 1 LASER PRODUCT. 
LIGHT EMITTING DIODE - CLASS 1
LED PRODUCT.

z

Warning!

This is a Class A device. This equip-
ment may cause radio interference if
used in a residential area; in this
case it is the operator´s responsibili-
ty to take appropriate measures.

The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating instructions.

FCC Note:

This equipment has been tested and found
to comply with the limits for a Class A digi-
tal device, persuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful inter-
ference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio fre-
quency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the inter-
ference at his own expense.

,

Recycling Note:

After its use, this product has to be
processed as electronic scrap and
disposed of according to the prevai-
ling waste disposal regulations of
your community / district / country /
state.

Summary of Contents for RS2-4R

Page 1: ...nectors and up to two fiber optic ports 100 Mbit s ports The fiber optic ports to connect further more switches are available with FX interfa ces depending on the RS2 4R model with multimode singlemod...

Page 2: ...with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and corr...

Page 3: ...applied to the device as described in the operating instructions z Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel th...

Page 4: ...S2 4R runs a hard ware self test During operation an integra ted watch dog monitoring unit monitors the function of the software Reset The RS2 4R will be reset by the following actions management inpu...

Page 5: ...lduplex 1 0 Ring port 100 Mbit s fulldupl off 1 1 Ring port 100 Mbit s fulldupl on Tab 1 DIP switch function 1 9 INTERFACES 10 100 MBit s connection Twisted Pair 10 100 Mbit Ports 8 pin R45 sockets al...

Page 6: ...00 you can close the two ends of a line structured backbone to form a redundant ring The RS2 4R is integrated into the ring via the HIPER Ring ports ports 3 and 4 Within a redundant ring any mixture o...

Page 7: ...m version 5 5 on Note The Web based interface uses the plugin Java runtime environment version 1 3 If this is not installed on your compu ter an installation via the internet is started automatically...

Page 8: ...4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6...

Page 9: ...supply voltage 2 present 1 x red LED FAULT indicator contact is open and indicates error 1 x green yellow LED RM redundancy manager autoconfig adapter Port status 4 x green LED LS 1 to 4 link state 4...

Page 10: ...nd Network Solutions Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 49 7127 14 1551 E Mail ans support hirschmann de Internet http www hirschmann com Printed in Germ...

Reviews: