Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Note:
Applies for the device variants OCTOPUS ...Train BP:
Avoid the use of the ring manager function for port 4 and port 8 (relay
ports).
Deactivate the Spanning Tree Protocol if you use the relay ports as data
rate 10 Mbits/s.
Use the same port configuration for the relay ports.
The device features the following options:
Auto-negotiation with autocrossing
MDI or MDIX
Half duplex or full duplex
10 Mbit/s or 100 Mbit/s
Test the device configuration for flawless operation by switching off the
current to the devices connected via relay ports.
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: deactivated
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation
Ring manager disabled