![Hirschmann MACH104-20TX-F Series User Manual Download Page 28](http://html1.mh-extra.com/html/hirschmann/mach104-20tx-f-series/mach104-20tx-f-series_user-manual_2138025028.webp)
28
MACH104
Release 09/09
Port state
These LEDs display port-related information.
2.3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
X
Entry via V.24 connection
X
Entry using the HiDiscovery protocol
X
Configuration via BOOTP
X
Configuration via DHCP
X
Configuration via DHCP Option 82
X
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
"Basic Configuration" user manual on the CD ROM.
Default settings
X
IP address: The device looks for the IP address using DHCP
X
Management password:
user, password: public (read only)
admin, password: private (read and write)
X
V.24 data rate: 9,600 Baud
X
Ring redundancy: off
X
Ethernet ports: link status is not evaluated (signal contact)
LS - link status (one green LED per port)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 time a period) Port is switched to stand-by.
Flashing green (3 times a peri-
od)
Port is switched off.
DA - data (one yellow LED per port)
Flashing yellow
Receive data / send data.
LS
DA
2
LS
DA
1