![Hirschmann MACH104-16TX-PoEP+2X-E-L2P User Manual Download Page 37](http://html1.mh-extra.com/html/hirschmann/mach104-16tx-poep-2x-e-l2p/mach104-16tx-poep-2x-e-l2p_user-manual_2138023037.webp)
Installation MACH104
Release 08 01/2019
37
6
Technical data
6.1
General technical data
Dimensions
See “Dimension drawings” on page 38.
Weight
MACH104-20TX-F...
9.26 lb (4.2 kg)
MACH104-20TX-FR...
9.7 lb (4.4 kg)
MACH104-20TX-F-4-PoE...
10.14 lb (4.6 kg)
Supply voltage
Rated voltage range
100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Voltage range including
maximum tolerances
90 V AC ... 265 V AC, 47 Hz ... 63 Hz
Current
consumption
Rated current for devices
without PoE
max. 0.3 A (240 V AC)
max. 0.5 A (100 V AC)
Rated current for devices with
PoE
max. 0.9 A (240 V AC)
max. 1.7 A (100 V AC)
Activation current
typ. < 40 A at 265 V AC and cold start
PoE power
Maximum number of Powered
Devices (PDs)
This applies to the following device
variants only:
MACH104-20TX-F-4-PoE...
4 × Powered Device (PD) Class 0 (15.4 W)
Power loss buffer
> 12 ms (115 V AC)
Overload current
protection at input
Non-replaceable fuse
Climatic conditions
during operation
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
+32 °F ... +122 °F (0 °C ... +50 °C)
Humidity
20 % ... 90 %
(non-condensing)
Air pressure
min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (
−
1312 ft;
−
400 m)
Climatic conditions
during storage
Ambient air temperature
b
b. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
–4 °F ... +185 °F (
−
20 °C ... +85 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (
−
1312 ft;
−
400 m)
Signal contact
Switching current
max. 1 A, SELV
Switching voltage
max. 60 V DC or max. 30 V AC, SELV
Connection type
2-pin terminal block
max. conductor cross section AWG16
(1.3 mm²)
Tightening torque 2.2 lb-in (0.25 Nm)
Pollution degree
2
Protection classes Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP30
Summary of Contents for MACH104-16TX-PoEP+2X-E-L2P
Page 49: ...Installation MACH104 Release 08 01 2019 49...
Page 50: ......