Hirschmann GHV 20 M Operating Instructions Manual Download Page 5

5

c

Type

GHV 20 M

Order No.

940 030-061

Frequency range  

vorward  

MHz

85...862

return

MHz

5...65

Gain 

Output 1

dB

0

12 

Output 2, 3, 4

dB

-

10.5

Level adjuster 

dB

0...-20

Noise figure

dB

Return loss

dB

17

16 

(min. categ. C) (min. categ. C) 

Impedance

75 

Output level, IMA = 60 dB

IMA 2 acc. EN 50083-3 

dBµV 

90

IMA 3 acc. EN 50083-3 

dBµV 

97

IMA 3 acc. EN 50083-5 

dBµV 

103

CSO Cenelec 42 ch. 862 MHz 

dBµV

87

CTB Cenelec 42 ch. 862 MHz 

dBµV 

90

Connected loads

Supply voltage (50 – 60 Hz)

VAC

230 

Power consumption

W

Ambient conditions to EN 60065

Operating temperature range

°C 

– 25 … +55 

Degree of protection

II, totally insulated

Protection class

IP 20

Housing

Weight

kg

approx. 0.65 

Dimensions W x H x D

mm

150 x 80 x 50

Screening attenuation 

acc. EN 0083-2, class A

dB

75 min

RF connections

F connectors

Unless otherwise stated, these specifications are typical values which in practice may be higher or lower inside the
tolerance range usual for the branch.

Technical Data

2. Adjust the level control (Fig. 2):

Adjuster screw (c) full to right = 0 dB (delivery
condition), full to left = -20 dB

3. Close the housing lid:

Put the housing lid on the housing and press
all the way round. The sheet steel segments
will now be pressed against the inner wall of
the housing. Screw in the central screw.

Fig. 2

Summary of Contents for GHV 20 M

Page 1: ...V 20 M eco power Best Nr Order code Best nr 940 030 061 Multimediaf higer Hausan schlu verst rker mit 4 Ausg n gen zum Einsatz in kleineren Geb udeeinheiten und in CATV Hausnetzen Multimedia capabilit...

Page 2: ...0083 1 EN 50083 2 Klasse A EN 50083 3 G teklasse 2 Beschreibung D Dieses Produkt ist nach seiner Verwen dung entsprechend den aktuellen Ent sorgungsvorschriften Ihres Landkreises Landes Staates als El...

Page 3: ...ngungen gem EN 60065 Betriebstemperaturbereich C 25 55 Schutzart II schutzisoliert Schutzklasse IP 20 Geh use Gewicht kg ca 0 65 Abmessungen B x H x T mm 150 x 80 x 50 Schirmd mpfung gem EN 0083 2 Kla...

Page 4: ...life it is to be turned in for proper disposal as electronic refuse in compliance with the current disposal regulations of your respective city country state Recycling Information CAUTION Observe the...

Page 5: ...g temperature range C 25 55 Degree of protection II totally insulated Protection class IP 20 Housing Weight kg approx 0 65 Dimensions W x H x D mm 150 x 80 x 50 Screening attenuation acc EN 0083 2 cla...

Page 6: ...abel configureren mogelijk Het basishuis van spuitgegoten ijzer verlaagt de temperatuur van de onderdelen en verhoogt daarmee de levensduur en de betrouwbaarheid HF Anschl sse F Buchsen 3 3 3 3 Voldoe...

Page 7: ...065 Bedrijfstemperatuurbereik C 25 55 Beschermklasse II ge soleerd Beschermtype IP 20 Huis Gewicht kg approx 0 65 Afmetingen b x h x d mm 150 x 80 x 50 Afschermdemping volgens EN 0083 2 klasse A dB 75...

Page 8: ...2654 Neckartenzlingen Tel 0180 32 32 341 www hirschmann com Betriebsanleitung GHV 20 M Operating instructions GHV 20 M Handleiding GHV 20 M Hirschmann Electronics B V Pampuslaan 170 NL 1382 JS Weesp T...