Hirschmann Dragon PTN Series User Manual Download Page 13

3.

 

MODULE SPECIFICATIONS

 

3.1

 

General Specifications

 

For general specifications like temperature, humidity, EMI... see Ref.[5] in Table 1. 

 

3.2

 

Other Specifications

 

 

Table 5 Other Specifications

 

 

Description

 

Value

 

Weight 

0.23 kg / 0.5 lb 

MTBF 

87 years at 25°C/77°F 

Power Consumption 

8.4 W (measured at 25°C/77°F) 

Module Size 

width: 

20.32 mm / 0.8 inches 

height:  126 mm / 4.96 inches 

depth: 

195 mm / 7.68 inches 

 

3.3

 

Ordering Information

 

    

2-OLS with E1: future support; 

   

2-OLS with T1: future support; 

 

4.

 

ABBREVIATIONS

 

AIS 

Alarm Indication Signal 

AMI 

Alternate Mark Inversion 

CE 

Conformité Européenne 

CSM 

Central Switching Module 

DC 

Direct Current 

EMI 

Electromagnetic Interference 

ERR 

Error 

ETH 

Ethernet 

FLT 

Fault 

HDB3 

High Density Bipolar of Order 3 

IEEE 

Institute of Electrical and Electronics Engineers 

IFM 

InterFace Module 

kbps 

Kilobit per Second 

LAN 

Local Area Network 

LOF 

Loss Of Framing 

LOS 

Loss Of Signal 

LVD 

Low Voltage Directive 

Interface Module PTN-2-OLS with E1/PTN-2-OLS with T 

Release 01 02/2018 

13 

 

Summary of Contents for Dragon PTN Series

Page 1: ...anual Installation Dragon PTN Interface Module PTN 2 OLS with E1 PTN 2 OLS with T1 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T1 Technical Support Release 01 02 2018 https hirschmann support belden com ...

Page 2: ...ave been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no re...

Page 3: ...al Switching Module CSM 11 2 2 8 Test and Loopback Selftests 11 2 3 Onboard Interfaces 12 2 3 1 Straps 12 2 3 2 DIP Switches 12 3 MODULE SPECIFICATIONS 13 3 1 General Specifications 13 3 2 Other Specifications 13 3 3 Ordering Information 13 4 ABBREVIATIONS 13 List of figures Figure 1 2 OLS SDH Example 5 Figure 2 Front Panel 6 Figure 3 Optical Serial ST Connector 8 Figure 4 E1 RJ 45 Connector 8 Fig...

Page 4: ... 6 Table 2 LED Indications In Boot Operation 7 Table 3 LED Indications In Normal Operation 7 Table 4 E1 RJ 45 Connector Pin Assignments 8 Table 5 Other Specifications 13 4 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T Release 01 02 2018 ...

Page 5: ...n side the 2 OLS receives the E1 traffic and converts it back to an optical low speed serial signal towards the end application In HiProvision Dragon PTN Management an Optical Low Speed Serial service can be configured between two optical ports each port located in a different node This service bundles together 32 TDM Time Division Multiplex connections resulting in a total bandwidth of 2 048 Mbps...

Page 6: ... refers to the manual issue All these manuals can be found in the HiProvision Dragon PTN Management System Help function Table 1 Manual References Ref Number Title 1 DRA DRM821 Dragon PTN and HiProvision Operation 2 DRA DRM801 Dragon PTN Installation and Operation 3 DRB DRM802 Dragon PTN Nodes PTN2210 PTN2209 PTN2206 PTN1104 4 DRB DRM803 Dragon PTN Switching Module PTN CSM310 A 5 DRA DRM810 Dragon...

Page 7: ...2 x Fast blinking 3 x 4 x Fast blinking x x x x x LED is lit LED is not lit The sub cycle times may vary The entire boot cycle time 1 4 takes approximately 2 minutes Table 3 LED Indications In Normal Operation LED Color Status PI Power Input Not lit dark 12V power input to the board not OK Green 12V power input to the board OK PF Power Failure Not lit dark power generation on the board itself is O...

Page 8: ... 2 OLS module provides two optical serial ports with each port having two ST Straight Tip connectors TX and RX These ports can be used for communication over optical fiber Figure 3 Optical Serial ST Connector 2 1 4 E1 RJ 45 Ports Copper and Cables The 2 OLS module provides two E1 ports and each port connector has eight pins Each port provides one tip ring pair See the table and figure below for an...

Page 9: ... for E1 HDB3 is an enhancement of AMI For this reason AMI is mentioned here as well As the E1 link has no separate clock transmission the receiver will derive the clock from the incoming data stream A minimum density of logical ones is required in order to guarantee a faultless clock recovery This is achieved basically by AMI which encodes the data stream with bipolar violations A more enhanced an...

Page 10: ...the optical serial RX ports FM0 encoded data is generated at the optical serial TX ports 2 2 5 Short Haul Long Haul on E1 Ports Long E1 links 200m Long Haul have more signal attenuation than shorter links 200m Short Haul As a result the signal levels or sensitivity 0 or 1 on the receiver side must be configured according the used link Long Haul or Short Haul In HiProvision a Short Haul parameter c...

Page 11: ... will operate as well because 2 OLS samples at 6 6 times the selected bitrate E1 Ports Short Haul see 2 2 5 unchecked default checked 2 2 7 I O with the Central Switching Module CSM The CSM is only needed to program the 2 OLS IFM via HiProvision Once the 2 OLS IFM has been configured it does not need the CSM anymore 2 2 8 Test and Loopback Selftests Test and Loopback selftests can be performed via...

Page 12: ...tes Hardware Edition 5 dec Figure 9 Hardware Edition b E1 T1Configuration The E1 T1 configuration of the 2 OLS module is factory set by the S1 DIP switch into E1 mode and must not be changed The configuration can be read out via HiProvision Switch E1 both E1 T1 ports operate as E1 ports use the 2 OLS E1 L IFM in HiProvision Switch T1 future both E1 T1 ports operate as T1 ports use the 2 OLS T1 L I...

Page 13: ...3 Ordering Information 2 OLS with E1 future support 2 OLS with T1 future support 4 ABBREVIATIONS AIS Alarm Indication Signal AMI Alternate Mark Inversion CE Conformité Européenne CSM Central Switching Module DC Direct Current EMI ElectromagneticInterference ERR Error ETH Ethernet FLT Fault HDB3 High Density Bipolar of Order 3 IEEE Institute of Electrical and Electronics Engineers IFM InterFace Mod...

Page 14: ...Time Between Failures OLS Optical Low Speed PF Power Failure PI Power Input PTN Packet Transport Network PTP Point to Point RAI Remote Alarm Indicator SDH Synchronous Digital Hierarchy SF Super Frame ST Straight Tip TDM Time Division Multiplex 14 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T Release 01 02 2018 ...

Reviews: