![Hirschmann BATOne User Manual Download Page 46](http://html1.mh-extra.com/html/hirschmann/batone/batone_user-manual_2138086046.webp)
8.7
EMC and immunity
Note:
You will find detailed information on the certificates and declarations
applying to your device in a separate overview.
EMC interference
emission
Standard
applications
Railway applications
(trackside)
Radiated emission
EN 55032
Class A
Class A
EN 61000-6-4
Fulfilled
Fulfilled
Conducted emission
EN 55032
AC supply
connection
Class A
Class A
EN 61000-6-4
AC supply
connection
Fulfilled
Fulfilled
EN 55032
Telecommunication
connections
Class B
Class B
EN 61000-6-4
Telecommunication
connections
Fulfilled
Fulfilled
EMC interference
immunity
Standard
applications
Railway
applications
(trackside)
Electrostatic discharge
EN 61000-4-2
Contact discharge
± 4 kV
± 6 kV
EN 61000-4-2
Air discharge
± 8 kV
± 8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 6000 MHz
10 V/m
20 V/m
Fast transients (burst)
EN 61000-4-4
AC supply connection
± 2 kV
± 2 kV
EN 61000-4-4
Data line
± 1 kV
± 2 kV
Voltage surges - AC supply connection
EN 61000-4-5
line/ground
± 2 kV
± 2 kV
EN 61000-4-5
line/line
± 1 kV
± 1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
± 1 kV
± 2 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
Power frequency magnetic fields
EN 61000-4-8
—
300 A/m
Installation BATOne
Release 01 01/2019
46