Installation
3A6823A
9
Mount the Pump and Connect
Fluid Supply
NOTE:
A strainer (F) or fluid filter is required before the
pump inlet. This will keep debris from the fluid supply
container from reaching the pump and check valve
seals. For maximum performance, the inlet port (K)
should be mounted below the fluid supply container.
1.
Mount the pump (E) and connect the fluid inlet
line (J).
Connect Pneumatic Supply
1.
Install the pressure regulator (D) and gauge to con-
trol the inlet pressure. See
your model’s maximum pneumatic pressure.
2.
Install a pneumatic line filter (B) to keep debris from
affecting pump performance and to increase pump
life.
3.
Connect the outlet of the master valve (C) to the 1/2
in. female NPT port on the Intensifier pump (E).
Connect Fluid Outlet
1.
Connect a fluid line from the outlet port (L) to the
hydraulic system.
2.
Install a fluid pressure relief valve (H) on the outlet
side of the pump.