Insert 3 AA-size 1.5V alkaline batteries to the battery compartment, ensuring correct polarity
is put (Fig.3).
Fig.3
4)
Two ways of mounting are applicable to the detector. Decide the detector is to be
wall-mounted (Fig.4) or ceiling-mounted (Fig.5). Hold the rear cover in position and mark
the two mounting holes. Drill the holes, insert the plastic wall plugs and screw the rear cover
to the wall or ceiling using the screws provided.
5)
Engage the detector to rear cover firmly.
i.
Wall Mounting
The recommended position for wall mounting is at the height of 1.8m from the flood. At
this height, the optimum detection range is up to 10m with coverage range of 110
degrees.
Fig.4
ii.
Ceiling mounting
The recommended position for wall ceiling mounting is at the height of 2.8m from the
flood. At this height, the optimum detection range is up to 5m with coverage range of 360
degrees.