HIOTH TECHNOLOGY CO., LTD CT-SMZW2004-ES User Manual Download Page 2

 

    

HIOTH

                                          User Manual

 

HIOTH TECHNOLOGY CO.,LTD. 

Technical Information 

 

Compatible with any Z-Wave network controller 

 

Battery powered and cost savings 

 

Support the scene control 

Specifications

 

 

Radio protocol: Z-Wave    868.42MHz EU 

 

Power supply: DC 4.5V(1.5V AA*3) 

 

RF range

25m (in an open area of the wireless controller and the latest line-of-sight between 

Z-Wave receiving module) 

 

Operation Frequency: 908.42 MHz (SP814-2) / 921.42 MHz (SP814-9) 

 

PIR Detection Coverage: Wall-Mounted: 

                                                  Up to 10m x 110 ° (at 1.8m mounting height& 25 ° C) 

                                                Ceiling-Mounted: 

                                                 

Up to5m x 360 ° (at2.8m mounting height& 25 ° C) 

 

Dimension

85 mm x 85 mm x 45 mm   

Operation  

NOTE: 

 

Lens Cover 

 

Photocell Sensor 

 

PIR Sensor 

 

Two-Color Indication LED(red & green) 

Summary of Contents for CT-SMZW2004-ES

Page 1: ...Inclusion of this Motion Detector on other manufacture s Wireless Controller menu allows remote turn on of connected modules w hen the detector is triggered The Motion Detector is designed with two detecting sensors Passive Infra Red PIR sensor and light sensor in order to fulfill the purpose of security and home automation Once night falls the percentage of ambient illumination is lower than pres...

Page 2: ... 5V AA 3 RF range 25m in an open area of the wireless controller and the latest line of sight between Z Wave receiving module Operation Frequency 908 42 MHz SP814 2 921 42 MHz SP814 9 PIR Detection Coverage Wall Mounted Up to 10m x 110 at 1 8m mounting height 25 C Ceiling Mounted Up to5m x 360 at2 8m mounting height 25 C Dimension 85 mm x 85 mm x 45 mm Operation NOTE Lens Cover Photocell Sensor PI...

Page 3: ...te of No node ID 2 second on 2 second off 2 Choose Z Wave to enter the Network Inclusion mode on the APP then click 3 Pressing link key 3 times within 1 5 second Detector beeps when link key is pressed 4 When prompt a message Request Access Success please go to the device list interface and refresh the device list the device will be displayed Z WAVE NETWORK EXCLUSION 1 Make sure the device is conn...

Page 4: ...ta 1 Make sure the device is connected to the power supply 2 Pressing link key 3 times within 1 5 second Detector beeps when link key is pressed 3 Within 1 second press and hold the link key until beep stops A long beep is sounded for 5 seconds 4 IDs are excluded and all of preset value will be reset to factory default 2 second on 2 second off Installation Instructions It s recommended to install ...

Page 5: ... the holes insert the plastic wall plugs and screw the rear cover to the wall or ceiling using the screws provided 5 Engage the detector to rear cover firmly i Wall Mounting The recommended position for wall mounting is at the height of 1 8m from the flood At this height the optimum detection range is up to 10m with coverage range of 110 degrees Fig 4 ii Ceiling mounting The recommended position f...

Page 6: ...ounted whereas ceiling lens cover Fig 6b is to be used when the detector is ceiling mounted The coverage range adjustment is only applicable to ceiling lens cove choose correct lens cover before mounting Fig 6a Fig 6b NOTICE 1 The shading cap is composed of 12 segments for limiting the detection coverage and each segment covers detection angle of 30 degrees Fig 6c Follow the grooves on the cap cut...

Page 7: ...he ceiling lens cover without shading cap No movements can be detected if the detector is reloaded with a shading cap which maintains 12 lens segments Safety Notice Don t make the device directly to the window fan air conditioner or sunlight Do not install the device above or facing any source of heat directly such as fires radiators boilers etc Confirm the device is positioned in place where the ...

Reviews: