Summary of Contents for VZ SERIES

Page 1: ...A Operation Manual No ET A004 Electric Screwdriver Operation Manual November 2008 Transformerless Screwdriver VZ SERIES 100V Lever Start Type VZ 1510 Push To Start Type VZ 1510PS VZ SERIES 220 240V Lever Start Type VZ 1812 VZ 3007 VZ 4504 Push To Start Type VZ 1812PS VZ 3007PS VZ 4504PS ...

Page 2: ... clamps or vise to hold work It s safer than using your hand and it free both hands to operate tool 4 Guard Against Electric Shock Prevent body contact with grounded surfaces for example pipes radiators ranges refrigerator enclosures 5 Keep Children Away Do not let visitors contact tool All visitors should be kept away from work area 6 Store Idle Tools When not in use tools should be stored in dry...

Page 3: ...paired by authorized service facility Keep hand dry clean and free from oil and grease Inspect extension cords periodically and replace if damaged 15 Disconnect Tools When not in use such as attaching and detaching the bit changing the Carbon Brush inspection or cleaning etc disconnect tool 16 Avoid Unintentional Starting Be sure switch is off when plugging in Don t carry tool with finger on switc...

Page 4: ...should be properly repaired or replaced by an authorized service man or authorized service facility unless otherwise indicated elsewhere in this instruction manual 19 Outdoor Use Extension Cords When tool is used outdoors use only extension cords intended for use outdoors and so marked TABLE 1 MINIMUM GAGE FOR CORD SETSa Volts Total Length of Cord in Feet 120V 0 25 26 50 51 100 101 150 240V 0 50 5...

Page 5: ...ug that looks like that shown in Figure 1 An adapter see Figure 3 is available for connecting Figure 1 Type Plug to 2 prong receptacles The green colored rigid grounding strap must be con nected to permanent ground such as to a properly grounded outlet box COVER OF GROUNDED OUTLET BOX GROUNDING PIN GROUNDING MEANS ADAPTER Figure 1 Figure 2 Figure 3 For safe use of adapters the outlet box must be g...

Page 6: ... Balancer to hang the AC cord 8 For the safety use do not set the torque adjusting nut at higher than 10 on the torque adjusting scale Ref to P 14 9 Use the tool intermittently which describes on the tool ex 0 5sec on 4 5sec off 10 Do not tighten more than 720 pcs of tapping screws per 60 minutes 11 This tool is not for tightening up wood screw 12 During the motor is running never change the forwa...

Page 7: ...12PS VZ 3007PS VZ 4504PS Input AC 100V AC 220V 240V AC 220V 240V AC 220V 240V Power Consumption 26W 40W 40W 40W Output Torque N m 0 15 1 5 0 4 1 8 0 9 3 1 4 5 lbf in 1 3 13 3 5 16 7 8 26 8 8 39 Range kgf cm 1 5 15 4 18 9 30 10 45 Torque Switching Stepless adjustment Unloaded Rotation 1 000 1 200 700 400 Speed r p m 10 Small Size Screw 2 0 4 0 2 6 4 0 3 0 5 0 3 0 5 0 Tapping Screw 2 0 3 0 2 6 3 0 3...

Page 8: ...V VZ 1510 Push to start AC220V 240V VZ 1812 VZ 3007 VZ 4504 AC plug Power Cable Hanger Hanger Foward off reverse switch Foward off reverse switch Carbon brush cap Carbon brush cap Switch lever Switch lever Torque adjusting bolt Torque adjusting nut Bit Torque adjusting scale Joint shaft collar Carbon brush cap Carbon brush cap Adjsuting bolt Torque adjsut scale Torque adjust scale nut The Protecti...

Page 9: ...fixed value Release the Switch Lever to put the Bit off the screw By the repeat of these operation screw is tightened continuously Push to Start System is automatically released by moving the Bit away from screw head 8 To loosen the tightened screw turn the Forward Off Reverse Switch to REVERSE position When the screw can not be loosened tighten up the Torque Adjusting Nut Push to Start Type Both ...

Page 10: ...mly locked after it has been attached The VZ 1812 series and VZ 3007 series has a chuck to suit both the HIOS shank H5 Ø5 and the 5 mm wide hexagonal bit 5HEX Take note of the following precautions when using the hexagonal bit Always use our standard HIOS shank type bits H4 Ø4 and H5 Ø5 Types of driver bits that can be used with the VZ 1812 series and VZ 3007 series Caution 60mm H5 Ø5 HIOS Driver ...

Page 11: ...he Phillips adjustment screw supplied screw tightly into the driver bit chuck If the Phillips adjustment screw is not tightened for enough the driver bit will not be locked and may result in unreliable screw fastening Use the Phillips adjustment screw M2 6 Tighten the Phillips adjustment screw properly 6 3 5 9 0 W bit 9 0 Bits whose length from the point to the bearing groove is not 9 mm Double re...

Page 12: ... up the Torque Adjusting Nut In case of opposite loosen it Repeating the adjust ment find the most suitable point The VZ 1510 VZ 1510PS Electric Screwdriver have Double nut system Nut fixing ring and Torque adjusting nut to avoid loosening from shock or vibration to the driver To adjust those two nuts follows 1 to 3 steps below 1 At first stop the Nut fixing ring upper surface to fit the graduatio...

Page 13: ...he Carbon Brush Cap is changed pay attention to the direction of brush surface concav ity Insert the Brush to fit its surface to the Commutator s Slot on the side of Carbon Brush indicates Limit for Use Change the Brush when it is abraded over the Slot To keep the good condition we recommend to change it earlier Be careful so as not to tighten the Carbon Brush Cap too strongly Concave ...

Page 14: ...Z 3007 VZ 3007PS 1 5 1 2 5 3 3 5 4 4 5 2 1 2 3 4 5 6 7 8 9 10 VZ 4504 VZ 4504PS Bl Y Torque Scale 0 5 1 5 2 2 5 3 1 1 2 3 4 5 6 7 8 9 10 VZ 1812 VZ 1812PS W G Green R Red Bl Black W White Y Yellow Torque Adjustment Scale Upper edge of Nut N m 0 5 1 1 5 1 2 3 4 5 6 7 9 8 N m VZ 1510 VZ 1510PS Torque Scale G R ...