- 3 - 

 

Dis- 

play   

Mode (default) 

Symbol 

Description 

(1) 

Counter 

 

 

 

 

On:      When selected, the counter function is available. 
OFF:    When selected, it is used as a normal driver.   

 

 

 

On/OFF

  

 

(2) 

Count 

 

 

The screw fastening count value is set.   

 

 

 

 

 

  Setting range: 1 to 99   

(3) 

Min. revolutions* 

 

 

 

 

The minimum numbers of motor revolutions .   

 

 

 

 

 

 

  Display range: 000

999, 

  Setting range : 000

999 

* Hundreds place is not displayed.   
  Fx. Min. no. is “110” but only “10” is displayed on the screen. 

 

 

Max. revolutions* 

 

 

The maximum numbers of motor revolutions 

 

 

            

 

 

 

  Display range: 000

999, 

  Setting range : 000

999 

* Hundreds place is not displayed.   
  Fx. Max. no. is “120” but only “20” is displayed on the screen. 

  Refer to “3. Value Setting for Each setup functions” on page 4 for details.   

 

 

 

 

 

 

If the detected pulse is smaller than the minimum or larger than the maximum, 
the red LED light (Fail) turns on.   

 

 

 

 

 

 

If the detected pulse is larger than the minimum and smaller than the maximum, 
the green LED light (Pass) turns on. 

(4) 

Work Reset Timer 

 

 

The buzzer sound time period after the work is completed is set. 

 

Setting range: 0.0

3.9 seconds   

Note: Set it based on the Reverse Count Timer set value. 

(5) 

Reverse Count Timer 

 

 

The time period until the Reverse Count is performed is set.   
Set the Work Reset Timer operation time based on the time period up to 
when the Reverse Count is performed. 

 

 

          

 

 

 

 

Setting range: 0.1

1.0 second   

 

 

 

 

 

 

(Note) It is available when the “Reverse Count Enable” has been set in the 

System setting.   

(6) 

System Setting 

 

 

Each buzzers and Reverse Count Enable/Disable is set up. 
The Setting is performed with a combination of the tenth digit and single unit 
digit. 

 

 

 

 

 

 

 

 2nd digit 

 

 

 

 

 

 

  

0: Buzzers Enable / Reverse Count Enable 

 

 

 

 

 

 

  

1: Buzzers Enable / Reverse Count Disable 

 

 

 

 

 

 

  

2: Buzzers Disable / Reverse Count Enable 

 

 

 

 

 

 

  

3: Buzzers Disable / Reverse Count Disable 

 

 

 

 

 

 

 

 1st Digit 

 

 

 

 

 

 

   

2: Driver shut off (Torque Up) buzzer Disable 

 

 

 

 

 

 

   

3: Driver shut off (Torque Up) buzzer Enable 

(7) 

Over Time 

 

 

This sets whether or not the Over Time/Short Time error is detected. 

 

  Short Time 

 

 

 

0: Neither of motor revolutions is detected.   

 

 

     

 

 

 

 

1: Only the minimum no. is detected.   

 

 

 

 

 

 

 

2: Only the maximum no. is detected. 

 

 

 

 

 

 

 

3: Both are detected. 

(8) 

Total no. of 

 

 

The total No. of the driver shut off is displayed.   

 

  the driver shut off 

 

 

This counts all the driver shut off regardless of whether the Count is On/OFF. 

 

 

 

 

 

 

 
 

 

 

How to read the values: 
2nd digit:

×

1 million cycles 

1st digit:

×

  100,000 cycles 

Summary of Contents for JUKUREN BLG-BC2 series

Page 1: ...anual August 2018 Note BLG BC2 I O Cable set is optional P N BLG BC2 3010 Contents BLG BC2 I O Cable Application software Including the instruction manual Communication specifications HIOS Inc 1 16 5 Akiyama Matsudo City Chiba Pref Japan 270 2223 TEL 81 47 392 2001 FAX 81 47 392 7778 NO ET A011 BC2 18A ...

Page 2: ... count is displayed The count decreases with each screw fastening operation and the remaining screw fastening count is displayed 2 Function display section The symbol corresponding to the function is displayed in the setup mode See page 3 3 F1 Button Press and hold the F1 button until the P then the On is displayed Continue to press the F1 button to scroll through the setup functions Press and hol...

Page 3: ...ton Press to confirm the reference values of Pass Fail including the acceptable range Example Assuming the reference values including the acceptable range are from 90 to 120 the Pass range is from 91 to 119 Note In order to complete Direct Teaching make sure to work through all the steps 1 4 5 F2 Button Press and hold until the buzzer sounds twice to complete Direct Teaching 6 All set List of setu...

Page 4: ...it based on the Reverse Count Timer set value 5 Reverse Count Timer The time period until the Reverse Count is performed is set Set the Work Reset Timer operation time based on the time period up to when the Reverse Count is performed Setting range 0 1 1 0 second Note It is available when the Reverse Count Enable has been set in the System setting 6 System Setting Each buzzers and Reverse Count En...

Page 5: ...The no of motor revolutions is displayed up to triple digits 3 Value Setting for Each setup functions Verify the hundreds 3rd digit Press the F2 Button to change the figure position for setting Change the value Pressing the F3 button increases the value one by one Press and hold the F1 button until the buzzer sounds twice to save the change 4 Change cycle count Press F1 Button for more than 2 sec ...

Page 6: ...ity The count is to be returned to the default value during the screw fastening operation Pressing the F3 button for 2 seconds or more resets the screw fastening count value If you fasten a screw after the driver turns counterclockwise There may be some difference in results of motor revolutions after the driver turns counterclockwise as the start position may have changed In this case the start p...