DT4281,DT4282 DIGITAL MULTIMETER Remote Operation Manual
P9/14
Command
Explanation
:CALC:PEAK:MAX?
Query measured peak maximum count value.
Syntax :CALC:PEAK:MAX?
Response <data×1>
<data> count value
Example; “3000”
:CALC:PEAK:MIN?
Query measured peak minimum count value.
Syntax :CALC:PEAK:MIN?
Response <data×1> count value
Example; “-3000”
:SYST:FILTER
Set the filter.
Syntax :SYST: FILTER <data×1>
<data> “0” (off) or “1” (on)
Example; “:SYST: FILTER 1”
Response “OK” or “CMD ERR”
:SYST:PEAK
Set the peak.
Syntax :SYST: PEAK <data×1>
<data> “0” (off) or “1” (on)
Example; “:SYST: PEAK 1”
Response “OK” or “CMD ERR”
:SYST:SLOW
Set the average.
Syntax :SYST: SLOW <data×1>
<data> “0” (off) or “1” (on)
Example; “:SYST: SLOW 1”
Response “OK” or “CMD ERR”
:SYST:CLEAR
Put the clear command.
Syntax :SYST: CLEAR
Response “OK”
:SYST:BLA
Set the auto backlight.
Syntax :SYST: BLA <data×1>
<data> “0” (off) or “1” (on)
Example; “:SYST: BLA 1”
Response “OK” or “CMD ERR”
:SYST:CPER
Set the DC4-20mA or DC0-20mA.
Syntax :SYST: CPER <data×1>
<data> “0” (4-20mA) or “1”(0-20mA)
Example; “:SYST: CPER 1”
Response “OK” or “CMD ERR”