background image

HEAD OFFICE :

81 Koizumi, Ueda, Nagano, 86-1192, Japan

TEL +81-268-28-0562 / FAX +81-268-28-0568 

E-mail: [email protected]

HIOKI USA CORPORATION :

6 Corporate Drive, Cranbury, NJ 08512 USA

TEL +1-609-409-9109 / FAX +1-609-409-9108

E-mail: [email protected]

DISTRIBUTED BY

All information correct as of Dec. 21, 2007.  All specifications are subject to change without notice.

8714E4-7ZM      Printed in Japan

HIOKI (Shanghai) Sales & Trading Co., Ltd. :

1904 Shanghai Times Square Office, 9 Huai Hai Zhong Road

Shanghai, P.R.China   POSTCODE: 200021

TEL +86-21-691-0090/0092  FAX +86-21-691-060

E-mail: [email protected]

Beijing Office :

A-2602 Freetown, 58 Dong San Huan Nan Road

Beijing, P.R.China   POSTCODE: 100022

TEL +86-10-5867-4080/4081  FAX +86-10-5867-4090

E-mail: [email protected]

Guangzhou Office :

Room 0, Profit Plaza, No.76, West Huangpu Road

Guangzhou, P.R.China   POSTCODE: 51062

TEL +86-20-89267/2676  FAX +86-20-892679

E-mail: [email protected]

Input from power-concent

POWER HiCORDER 

8714

-01

 

 (2ch model)

POWER HiCORDER 

8715

-01

 

 (4ch model)

CARRYING CASE 

9648

  Hard case type, for storing 

options

PAPER WINDER 220H

 

Paper width: 70 to 220 mm, 

using special-purpose AC 

adapter

RECORDING PAPER 

9234

 

18 m/ 59.06 feet length, 

  10 rolls/ 1 set

CARRYING CASE 

9391

  Soft case type, for storing options

  Holds more options than the 

9648

 

hard case

Included accessories:

 

AC ADAPTER 9418

-15

 

×

1, Recording paper 

×

1, Blank box 

×

1, Strap 

×

1, 

CONNECTION CORD 9197

 (

8714

-01

:

 

×

2, 

8715

-01

:

 

×

4), Application disk 

×

1

CLAMP ON PROBE 

9018

-10

 

Input from 10 to 500A

  40Hz to 3kHz for 0.2V AC output. 

BNC terminal

CLAMP ON PROBE 

9132

-10

 

Input from 20 to 1000A

  40Hz to 1kHz for 0.2V AC output. 

BNC terminal

LINE SPLITTER CT101A

 

For 100V/ 15A, 

convenient for measuring 

100V AC line current with 

clamp-on probe

Composition of options

 

Note:

 Product names appearing herein are trademarks or registered trademarks of various companies. 

CONNECTION CORD 

9217

  Insulation BNC-to-insulation 

BNC, use to connect to 

insulation-BNC terminal on 

Input Module

CONNECTION CORD 

9197

 

For up to 500V,

  1.5 m length

CONCENT INPUT CORD 

9448

 

Use for 100V commercial 

line, 2m length

WAVE PROCESSOR 9335

  Data conversion, print functions, 

waveform display, compatible with 

Windows 95/98/Me, Windows NT 

4.0/2000/XP

PC CARD 128M 9726

 

(128MB capacity)

 PC CARD 256M 9727

 

(256MB capacity)

PC CARD 512M 9728

 

(512MB capacity)

 PC CARD 1G 9729

 

(1GB capacity)

Supplied with PC 

Card adapter

CONVERSION ADAPTER 

9199

 

Banana-to-BNC, use to 

connect to insulation-BNC 

terminal on Input section

CLAMP ON AC/DC HiTESTER 

3284

 

20A or 200A AC/DC, with 

analog output of 1V f.s. DC, and 

waveform monitor output of 1V 

f.s. AC at 10Hz to 2kHz, or DC.

  Requires the 

AC ADAPTER 

9445

-02

/

-03

CLAMP ON LEAK HiTESTER 

3283

 

For leakage current measurement, 

includes 10mA to 200A ranges, 

with analog output of 1V f.s. DC, 

and waveform monitor output 

of 1V f.s. AC at 40Hz to 2kHz. 

Requires the 

AC ADAPTER 

9445

-02

/

-03

BATTERY PACK 

9447

 

7.2V, 2400mAh

CHARGE STAND 

9643

 

Independent of main unit the 

8714

-01

/8715

-01

, use with the 

AC 

ADAPTER 9418

-15

 

 to charge one 

Model 

BATTERY PACK 9447.

AC ADAPTER 

9418

-15

 

Universal 100 to 240 V AC, 

12 V DC/ 2.5 A output

AC ADAPTER 

9445

-02/-03

 

Use for the 

3283, 3284, 

3285

, for USA/CSA 

9445

-02

,  for EU 

9445

-03

OUTPUT CORD 

9094

 

Required along with the 

9199

 adapter to connect 

the 

3283/3284/3285

 to the 

8714

-01

 or 

8715

-01

CONVERSION ADAPTER 

9199

 

Banana-to-BNC, use to 

connect to insulation-BNC 

terminal on Input section

+

CLAMP ON AC/DC HiTESTER 

3285

 

200A or 2000A AC/DC, with 

analog output of 1V f.s. DC, and 

waveform monitor output of 1V 

f.s. AC at 10Hz to 1kHz, or DC.

  Requires the 

AC ADAPTER 

9445

-02

/

-03

AC ADAPTER 

9418

-15

 

Use for the 

9322

, 100 to 240 

V AC

DIFFERENTIAL PROBE 

9322

 

For inputs up to 2kV DC or 

  1kV AC, the 

9322

 requires 

the 

AC 

ADAPTER 9418

-15

1kV AC, 2kV DC input

Up to 450V AC input

Record Current Waveform

Record Current Waveform

PC Card Precaution

Use  only  PC  Cards  sold 

by 

HIOKI

.  Compatibility 

and  performance  are  not  

guaranteed for PC cards made 

by other manufacturers. You 

may be unable to read from or 

save data to such cards.

Not CE certified

Not CE certified

Not CE certified

Not CE certified

Input cords of included accessories are the 

9197

 only. For current 

measurement, please purchase the optional clamp-on probe, or clamp-on 

tester.

+

n

 Combination example: 2-channels, with current measurement

Main unit

Paper

Battery pack

Current up to 500A

Carrying case

Model number  × 

quantity

8714

-01

×1

924×1 (10 rolls)

9447×1

9018

-10

×2

991×1

n

 Combination example: 4-channels, with current measurement

Main unit

Paper

Battery pack

Current up to 500A

Carrying case

Model number  × 

quantity

8715

-01

×1

924×1 (10 rolls)

9447×1

9018

-10

×4

991×1

Reviews: